5. ERROR DETECTION AND INDICATION
• If the device notices an error during system start (when switched on) or during control, the green LED light will start flashing.
• The optical error indication stays active until the error is corrected.
• When multiple errors occur at the same time, only the first detected error will be indicated.
• After correction of the error, the device will restart automatically.
Status green LED
OFF
Flashes 2 x *
Flashes 3 x *
Flashes 4 x *
* LED turns ON and OFF 2, 3 or 4 times during 0.5 sec . 2 sec OFF in between two flashing sequences.
6. CONFIGURATION

6.1. Factory settings

Standard configuration for the device is as follows:
Address for video inputs 01 - 16
Address for video inputs 17 - 64
Step sequence general (for all devices)
Step sequence individual (for up to 16 internal units)
Stepping on/off
Stepping during speech connection on/off
Control function for step function
Control function for image switching
Control function for backwards stepping
Automatic stepping on/off
Time interval for automatic stepping
Changing up of the video input with the control function
(control function number = video input 01 ... 64) on/off
Direct switching with free protocols
24
Possible cause
Device gets no power
The a conductor is not connected
The a and P conductors are switched
or short circuited
Transfer error on CAT cable: cascade/
RJ45 connection
Remedy
Turn on the power supply or connect a P conductor
Switch the a and P conductors or resolve the short
circuit; device will return to standby
Check the P conductor for short circuit or check the
power supply; device will return to standby
Check the CAT cable and plug
01, 02, 03, 04 for the first four video inputs; all other inputs
are not assigned
not assigned
video input 01 - 02 - 03 - 04
deactivated
on
on
239
238
0 (= suppressed)
off
10 sec.
off
deactivated
EN