12. Software
Lindab PC software is included as part of the package, and allows a PC to be used for data transmission and admin-
istration .
You can use the software to create customers and measuring points/sequences in advance and upload them to the LT
600 .
The software can also be used to install updates of the LT 600 firmware as well as the PC software itself .
A USB cable is included for data transfer .
The software can also be used for other Lindab instruments, and a more detailed description is available separately .
13. Operation and maintenance
There are user serviceable parts inside the LT 600 . The device should never be opened by the user .
Only specially trained personnel can open the device.
CAUTION - DANGER TO LIFE! max. 230V 50Hz
The device requires no maintenance apart from the occasional application of light grease on the round sealing ring on
the 50 mm connections . (Silicone grease included)
To change the main fuse, unplug the device from the mains and pull the fuse holder out from the upper edge . The fine-
wire fuses must only be replaced with another fuse of the same type .
The measuring accuracy and operation of the device should be checked regularly (annual checks are suggested) at
the factory or by a suitably equipped testing centre .
Figure 5: Nameplate and device no .
The device should always have a filter pad fitted in the air intake during operation.
The air intake and outlet must be protected from dirt and moisture . It is essential to prevent dust and water entering
the unit .
Replace the filter pad on a regular basis . A loss of power may indicate dirt at the intake .
The device should only be run from stable electricity networks, not from generators or other supplies that are unable
to deliver continuous power .
The LT 600 has been approved for use as a measuring instrument . It should not ordinarily be used as a way of locating
leakages in duct systems, a process that can sometimes take hours . However, if it is necessary to maintain pressure
for an extended period, you can avoid overloading the fan unnecessarily by not using an adapter .
If the intake is used to try to locate a leakage, no smoke cartridges or mist of any kind may be used.
There is a risk of damaging the device.
17
manual-LTEST-1082_EN-DE-FR-SE.indd 17
2012-03-28 12:32:41