Setting The Air Pressure; Firing The Tool; Work Contact Element (Wce) - Power Fist 8558769 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

V 4.0

SETTING THE AIR PRESSURE

The amount of air pressure required depends on the size of the fasteners and the workpiece
material. Begin testing the depth of drive by driving a test nail into the same type of workpiece
material used for the actual job. Drive a test fastener with the air pressure set at 90-95 psi. Raise
or lower the air pressure to find the lowest setting that will perform the job with consistent
results. It may be possible to achieve the desired depth with air pressure adjustments alone.

FIRING THE TooL

The tool is specially designed for single sequential mode. This mode requires the trigger to be
pulled each time a fastener is driven. The tool can be actuated by depressing the WCE against
the work surface followed pulling the trigger.
The trigger must be released to reset the tool before another fastener can be driven.
WARNING: Always know the operational mode of the tool before using. Failure to know the
operational mode could result in death or serious personal injury.
WARNING: An improperly functioning tool must not be used. Do not actuate the tool unless
the tool is placed firmly against the work place.

WoRk CoNTACT ELEMENT (WCE)

1.
Disconnect the air supply from the tool.
2.
Remove all fasteners from the magazine.
3.
Make sure the trigger and work contact element move freely up and down without
sticking or binding.
4.
Reconnect air supply to the tool.
5.
Depress the work contact element against the work surface without pulling the trigger.
The tool must not operate. Do not use the tool if it operates without pulling the trigger.
Personal injury may result.
6.
Remove the tool from the work surface. The work contact element (WCE) must return
to its original down position. The tool must not operate. Do not use the tool if it
operates while lifted from the work surface. Personal injury may result.
7.
Pull the trigger and depress the work contact element(WCE) against the work surface.
The tool must not operate.
8.
Depress the work contact element (WCE) against the surface. Pull the trigger, the tool
must operate.
CAUTION: Check the operation of the work contact element trip mechanism before each
use. The WCE must move freely without binding through its entire travel distance. The
WCE spring must return the WCE to its fully extended position after being depressed. Do
not operate the tool if the WCE trip mechanism is not operating properly. Personal injury
may occur.
10