Configuration Telegram; Digital Input And Output - Leuze electronic MSI-FB-PB-100 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Configuration telegram

The MSI-FB-PB100 realizes a modular slave. Depending on the configuration, it differentiates between
the "Automatic system configuration" and the "Configuration via DTM" operating modes.
During the automatic configuration, the gateway creates the MSIM configuration and saves it in the
connected slaves. The device addresses of the connected system devices must be manually assigned
before. This operating mode should be used only for extremely small stations.

6.1. Digital Input and Output

The "Digital inputs / outputs" module is always active.
It must always be initialized as the first module by the configuration telegram.
This is usually ensured by the settings in the GSD file. If this GSD function is not supported by the
PROFIBUS configuration tool, this must be ensured by the user.
• Process output data
Bit
Description of Digital Output
0
O1: Digital output 1
1
O2: Digital output 2
2
O3: Digital output 3
3
O4: Digital output 4
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
28
• Process input data
Bits I1 .. I8 reflect the status of the digital inputs of the
gateway.
Bit
Description of Digital Input
0
I1: Digital input 1
1
I2: Digital input 2
2
I3: Digital input 3
3
I4: Digital input 4
4
I5: Digital input 5
5
I6: Digital input 6
6
I7: Digital input 7
7
I8: Digital input 8
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved