ULTRAFLEX
3.3 Hose installation
The two fittings mounted on the cylinder body are already oriented and are ready to be used.
DANGER
The fittings mounted on the cylinder cannot be oriented. If they are
unscrewed, they could be broken and the cylinder is no more usable.
WARNING
An excessive hose bend could result in its internal breaking which
will cause a bad operation of the system. In this case it is necessary to
replace the damaged hose.
Connect the flexible hoses supplied (1) to the cylinder and
to the fittings supplied (2) by tightening the nuts with ogi-
ve (3) by means of an open end wrench 22 mm (0.86")
with a torque of 45-50 Nm (33.2-36.9 lb-ft).
Connect the rigid tubes (4) to the pump (2) and to the fittings
(2) in the same way.
NOTICE
The installation of the rigid tubes (4) (cutting, bending and routing) must be carried out by specialized staff
by following the instructions of the manufacturer.
If copper or steel tubes are used, rinsing is required.
page 12
of 64 -
HYDRAULIC CYLINDER FOR INBOARD ENGINE
Installation and Maintenance Manual
4
2
3
1
YES
NO
1
3