Pumping Down; Connecting An Interface (Option) To The Air Conditioner - Mitsubishi Electric MLZ-KP25VF Notice D'installation

Masquer les pouces Voir aussi pour MLZ-KP25VF:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22

6. PUMPING DOWN

Refer to the procedures indicated in the installation manual of the outdoor unit.
When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes. The compressor may burst if air etc. get into it.

7. CONNECTING AN INTERFACE (OPTION) TO THE AIR CONDITIONER

• Connect an interface to the indoor control board of an air conditioner with a connecting cable.
• Cutting or extending the connecting cable of the interface results in defects in connecting. Do not bundle the connecting cable together with power supply
cord, indoor/outdoor connecting wire, and/or earth wire. Keep as much distance as possible between the connecting cable and those wires.
• The thin part of the connecting cable should be stored and placed where customers cannot touch it.
Room air conditioner
1) Fix the cable tie to the connecting cable at 270 mm from the edge of the insulation coating part. Attach the mounting cord clamp (medium) to the interface
side of the cable tie.
Mounting cord clamp (medium)
2) Remove the grille. (If the grille has been already installed)
3) Remove the electrical cover (1), (2).
Refer to 2-4. CONNECTING WIRES FOR INDOOR UNIT.
4) Slide out the indoor control board, and connect the connecting cable to CN105 on the indoor control board.
5) Remove the screw shown in the photo blow. Route the connecting cable according to the photo below. Fix the mounting cord clamp (medium), which has
attached to the connecting cable, with the screw.
6) Reinstall the indoor control board and the electrical cover (1), (2).
7) Reinstall the grille.
Fix the connecting cable at the prescribed position securely.
Incorrect installation may cause electric shock, fire, and/ or malfunction.
WARNING
Thin part of the connecting cable. Place this part
where customers cannot touch it.
Indoor control board
CN105
Thick part of the connecting cable
Cable tie
270 mm
Connecting cable
Mounting cord clamp
(medium)
WARNING
Main body of an interface
Connector
Insulation coating part
Screw
Cable tie
En-10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mlz-kp35vfMlz-kp50vf

Table des Matières