Appropriate Use; Performance And Speci¿ Cations; Operation - Lincoln 85562 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Appropriate Use

These lubrication units were designed to be used in outdoor
locations and hold 800 lbs of grease.
The maximum speci¿ cation ratings should not be exceeded.
Any other use not in accordance with instructions will result in
loss of claims for warranty and liability.
Performance and Specifi cations
Operating Temperature, °F (°C)
Operating Voltage, Solar powered Unit
Operating Voltage*, AC units
Maximum Current draw @ 24 VDC
Pump output/revolution in³ (cm³)
Unit performance
Max Unit outlet pressure PSI (BAR)
Reservoir Capacity Lbs (Kg)
*All pumps and controllers operate on 24 VDC. The AC units are
equipped with an AC to DC power supply to drop the AC input
voltage to 24 VDC
** .036 oz, assuming grease with a density of 7.5 lb/gal
Do not exceed maximum rated outlet pressure for
these pumps. Exceeding rated pressure may result in
damage to system components and personal injury.
"On" Time Setting
(Duration)
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
4 Sec
8 Sec
14 Sec
Form 403834
SHOP ONLINE at www.airlinehyd.com
LINCOLN WAYSIDE LUBRICATOR
-40 to 120
(-40 to 49)
24 VDC
(18 MIN, 32 MAX)
90 to 264 VAC
16 amps
0.07 (1.5)**
See table 1
4000 (276)
800 (348)
WAYSIDE LUBRICATOR SETTING CHART
Counter Setting
Total Wheel Count
(Axle Count)
(Activation)
16
32
12
24
10
20
8
16
6
12
5
10
4
8
2
4
1
2
1
2
1
2
1
2
Table 1
85562, 85563, 85564, 85565

OPERATION

The unit will dispense grease whenever it senses and counts
the preset number of axles passing the sensor. As long as
the unit is turned "on", it will remember the wheel count of the
previous train. For example, if the count is set for 10 axles and
only four counts were detected before the last train passed the
sensor, only 6 axles from the next train will be required before
the pump starts running again. The count resets if power is
interrupted.
From table one, it can be seen that grease output from the
pump can be increased by decreasing the axle count, or by
increasing the pump run time. No axles are counted while the
pump is running, so even when the axle count is set for "1", the
pump will turn "off" and then "on" with a slight delay between
cycles. If the amount of grease needs to be increased or
decreased, use table one to ¿ nd the proper setting. The grease
will dispense more evenly with more numerous and shorter
pump "on" cycles.
The side of the track that has constant gage face and wheel
À ange contact will tend to have a more À attened brush. This is
a normal condition. The brush will still bridge the gap between
the wheel À ange and the track gage face if the wheel À ange
should move slightly away from that rail. The grease will rest
on the brush tips and be in the proper position to be carried
away by the wheel À ange.
The grease reservoir is ¿ lled from the top through a 16-inch in
diameter cover. While the pump does have an inlet screen to
protect it from debris, care should be taken to insure the cleanli-
ness of the grease.
Pump Flow Rate
(Oz/Min)
0.93
1.14
1.30
1.48
1.74
1.91
2.12
2.70
3.12
3.38
3.53
3.60
Grease Applied
(Oz/Wheel)
0.003
0.004
0.004
0.005
0.005
0.006
0.007
0.008
0.010
0.011
0.011
0.011
Page Number - 3
800-999-7378

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

855638556485565

Table des Matières