The control unit with microprocessor RI.10KI can be used to control motors featuring a power not
exceeding 750W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically detached, or adequately insulated by
an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that settings of the Dip-switches are the required ones.
f) When the unit is powered, the LED "POWER" must light on. In the negative, check the good
condition of fuses and the presence of 230Vac, 50Hz between terminals 1 and 2 (INPUT 230VAC
- follow phase/neutral).
g) All normally closed inputs, which are not in use, should be short-circuited with the relevant Dip-
Switch located near the connection terminal of the inputs.
h) If the rotation direction of the motor is inverted, it is sufficient to invert the wires "APRE" - "CHIUDE"
(OPEN - CLOSE) of the motor as well as the limit switches wires "FCA" - "FCC".
Input/Output functions
Terminal
Function
No.
(1,2)
Input, 230VAC
(3,4,5)
Output, Motor
(6,7)
LAMP
(8)
CHIUDE
(9)
APRE
(10)
P.P.
(11)
STOP
(12)
FTC
(13)
FCA
(14)
FCC
(15,16)
+V
(17)
ASC
(18)
Input, common to
the safety edges
(19)
ASA
(20,21)
SCA
(22,23)
OUT 24VAC
(24,25)
Output,2nd chan-
nel
(26,27)
Input, antenna
(28,29)
Input, 24VAC
(30,31)
Capacitor
(32,33)
Output, 230VAC
RTX
Connector to the receiving card of the remote control.
RI10KI Control unit with microcontroller

GENERAL WARNINGS

Description
Power supply of the control unit 230Vac, 50Hz (Phase: terminal 1,
Neutral: terminal 2).
Respectively, Move(3), Move(4) and Common (5).
To the flashing light at 230Vac
Input, CLOSE push-button Normally Open (N.O.) contact
Input, OPEN push-button N.O. contact (it can be switched to "Pe-
destrian" input)
Input, STEP-BY-STEP push-button
Input, STOP push-button Normally closed (N.C.) contact
Input, safety devices connection, N.C. terminal (e.g. photocells)
Input, opening limit switch. N.C. contact
Input, closing limit switch. N.C. contact
Output, common for all inputs
Input, safety edge. Its activation causes the movement reversion for
1 second if the motor is in the closing phase*
Input, common of safety edges. The safety edges MUST NOT BE
CONNECTED TO THE COMMON OF THE PUSH-BUTTONS
Input, safety edge. Its activation causes the movement reversion for
1 second if the motor is in the opening phase*
Open gate indicator light connection, 24 Vac/3W max.
Output, auxiliary power supply, 24Vac (1A max.)
N.O. contact, controlled by the second channel of the remote
control
Antenna connection for the receiving card of the remote control.
Shield= terminal 26
Connection to the secondary of the transformer, 24V
Connection to the capacitor
Connection to the primary of the transformer, 24V