22
Declaration of performance according
to Regulation (EU) 305/2011
No. Ci7/Ci7G-CPR-170824
PRODUCT
Product type
Type designation
Manufacturing number
Intended area of use
Fuel
MANUFACTURER
Name
Address
CHECKS
According to AVCP
European standard
Test institute
DECLARED PERFORMANCE
Essential characteristics
Reaction to fire
Minimum distance to combustible material
Risk of falling embers
Emissions from combustion
Surface temperatures
Cleaning options
Mechanical durability
Emissions of hazardous substances
Nominal output
Efficiency
Flue gas temperature in connector at nominal
output
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Markaryd, 1st September 2017
Insert lit with solid biofuels
Contura i7 / i7G
See rating plate on the insert
Heating of rooms in residential buildings
Wood
NIBE AB / Contura
Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
System 3
EN 13229/2001/A2:2004/AC:2007
Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,
has checked declared performance and issued test report no. RRF-29 17 4647
Performance
NPD
Rear: 90 mm
Side: 500 mm
Follow the given conditions in the installation
instructions.
Pass
CO
Pass
Pass
Pass
Pass
7 kW
77%
369°C
Business area manager NIBE STOVES
0,07 %
Harmonised technical
specification
EN 13229/2001/A2:2004/AC:2007