General instructions and regulations
• All local regulations including those referring to national and European standards must be observed when installing the appliance.
• Ensure there is sufficient ventilation / air supply in the room from which your stove gets the combustion air.
This is the room where the stove is installed if you do not use a wall or stove-base air-supply system.
• The stove is not suitable for a shared flue system.
• The appliance must be mounted to a wall having sufficient bearing capacity.
• Ensure adequate access for cleaning the appliance, the flue gas connection and the chimney.
• When installing the stove, take into account the minimum distances from the wall so as to avoid any fire risk.
The minimum distances (sizes in cm) are shown in the figure below.
Specifications Trias
• Nominal power of the stove is 10 kWatt.
• Flue gas mass flow = 9,9 g/s
• Appliance weight = 130 kg
• Minimum chimney draught = 8,0 Pa
• Flue gas temperature directly over the stove = 388 °C
44 GB