2.02 Dimensions and technical data (fi g. 2 - tab. 1)
Key
a1 Flow 1 1/4"
a2 Return 1 1/4"
a3 Boiler drain 1/2"
a4 Flue connection 120-130 mm
a5 Burner hole 105 mm
Tab. 1
Heat and D.H.W.
Model
(net) gas+oil
Max.
GE 3 - 25
27,8
GE 3 - 35
38,8
GE 3 - 45
49,9
GE 3 - 55
59,6
Working
Model
pressure
bar
GE 3 - 25
6
GE 3 - 35
6
GE 3 - 45
6
GE 3 - 55
6
N.B.: - Max. water temperature for the heating system is 90° C. - Min. water temperature for the heating
system is 45° C.
4
Heat and
D.H.W. output
Max.
25,0
35,0
45,0
54,1
Combustion
chamber
A
B
C
load loss
∆p mbar
400
750
380
0,1
400
750
480
0,15
400
750
580
0,15
400
750
680
0,2
Cod. 3540Z970 - 09/2011 (Rev. 00)
Fig. 2
Water capacity
element
dm
3
3
13
4
17
5
21
6
25
Combustion
Water load losses
chamber
volume
∆t 10
dm
3
20,15
1,8
28,21
4,2
36,27
7,2
52,39
Combustion
chamber lenght
mm
350
450
550
650
Weight
of unit
kg
∆t 20
-
115
1
145
1,6
175
11
2,3
205
GE3