INSTALL THE SQUEEGEE

1
See Figure 4. Slide the Squeegee Assembly (11) onto the squeegee mount bracket and tighten the Squeegee Mount Thumb Nuts (AA).
2
Connect the Recovery Hose (AB) to the squeegee inlet.
3
Lower the squeegee, move the machine ahead slightly and adjust the squeegee tilt and height using the Squeegee Tilt Adjust Knob (31) and Squeegee
Height Wheel (AC) so that the rear squeegee blade touches the fl oor evenly across its entire width and is bent over slightly as shown in the squeegee cross
section.
FIGURE 4

FILL THE SOLUTION TANK

Read the cleaning chemical label and calculate the proper amount of chemical to mix for a tank that holds 31 US gallons (120 liters).
Open the Solution Tank Fill Cover (35), then fi ll the tank 1/3 full of water, add the cleaning chemical, then fi ll up the tank the remainder of the way. NOTE:
Detergent machines can either be used conventionally with detergent mixed in the tank or the detergent system can be used. When using the detergent
dispensing system do not mix detergent in the tank. Plain water should be used.
CAUTION!
Use only low-foaming, non-fl ammable liquid detergents intended for automatic scrubber machine applications. Water temperature
should not exceed 130 degrees Fahrenheit (55 degrees Celsius).