Technical Data
Function
Function indicator
Function type/setting
Adjustment ranges
Power circuit
Rated voltage U
N
Rated power DC
Operating voltage range
Galvanic isolation between supply/Control circuits
Control circuits
Rated output voltage, S11 and S33 against S21
Input current/peak current at S12 and S31/S22
Input current/peak current at S34 and S35
Response time (manual start t
Minimum activation time t
M
Recovery time t
W
Release time t
(immediately switching contacts)
R1
Release time t
(delayed contacts)
R2
Synchronous time monitoring t
Permitted test pulse type t
TP
Max. line resistance per channel
Output circuits
Enabling current path 13/14 and 23/24
Enabling current path 37/38
Contact type
Contact material
Rating switching voltage U
n
Max. thermal permanent current I
Max. total current I² all enabling current paths
Utilisation category according to EN 60947-5-1
Short circuit protection, fuse/circuit breaker.
Conditional short-circuit current according to EN60947-5-1.
Mechanical service life
General Data
Air gap and creepage paths between the circuits
Rated voltage
Overvoltage category/Rated surge voltage
Pollution degree: inside/outisde
Protection class according to EN 60529 case/terminals
Ambient operating temperature and Storage temperature
Oscillations, sinusoidal according to EN 60068-2-6
Weight
Standards
Terminals and connection data
Single-core or finely stranded
Finely stranded with wire-end ferrule
AWG conductor size (only use Cu wires)
Maximum tightening torque
Stripping length
Leuze electronic GmbH + Co. KG
info@leuze.de • www.leuze.com
/autom. start t
)
A1
A2
(manual start)
S
per enabling current path
n
In der Braike 1 D-73277 Owen
Tel. +49 (0) 7021 573-0
3 LED, green
Time, continuous
0.15 - 3 s, 1.5 - 30 s
0.85 - 1.1 x U
25 mA / 100 mA
40 mA / 100 mA
30 ms / 700 ms
0.15 s - 3 s ±16%
1.5 s - 30 s ±16%
7.5 s - 150 s ±25%
≤ (5 + (1.176 x U
Normally open contact
Normally open contact, release-delayed
Forcibly actuated
Ag-alloy gold-plated
AC 230 V
5 A² bei +55°C (diagram "Total Current")
Immediately switching contacts
AC-15: Ue AC 230 V, Ie 4 A
DC-13: Ue DC 24 V, Ie 2 A
6 A gG, fuse integral < 100 A²s
EN 60664-1
III / 4 kV (Basic insulation)
IP 40 / IP 20
-25 to +55 °C / -25 to +75 °C
10 - 55 Hz / 0.35 mm
EN ISO 13849-1, EN 62061
Screw terminals
1 x 0.2 - 2.5 mm² /
2 x 0.2 - 1.0 mm²
1 x 0.25 - 2.5 mm² /
2 x 0.25 - 1.0 mm²
26 - 14
0.5 to 0.6 Nm (5 - 7 lbf-in)
DC 24 V
2.6 W
N
No
DC 22 V
200 ms
500 ms
25 ms
< 500 ms
< 1 ms
/U
- 1) x 100) Ω
B
N
6 A
Delayed contacts
AC-15: Ue AC 230 V, Ie 3 A
DC-13: Ue DC 24 V, Ie 3 A
1000 A
10
7
300 V
2 / 3
0.2 kg
Spring-loaded terminals
2 x 0.2 - 1.5 mm²
2 x 0.25 - 1.5 mm²
24 - 16
---
7 mm
We reserve the right to make changes
01/2018 - 50134621-01 - 6/23