d. Completely discharge condensation.
e. Wrap the power supply cable (34) around the cable winder (33) and insert the plug in the specific housing
(31) (Fig.21).
f. Remove the batteries from the remote control.
g. Place the appliance in its original packaging and store it in a fresh and dry environment, away from direct
exposure to sunlight.
Do not store the appliance in moist or particularly dirty environments.
Checks before resuming use of the air conditioner:
a. Clean the filters after a long period of inactivity of the air conditioner.
b. Check that the air outlet or inlet are not obstructed (especially after a long period of inactivity of the air
conditioner).
4.2.a - Discharging condensation
When condensation water in the lower tray reaches the predetermined level, the appliance emits a beep
and the LED (S9) lights up.
In this case:
a. Disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. Remove the drain cap (32) and the rubber cap (32a) (Fig.19).
Make sure you correctly tightened the drain cap (32) in order to avoid water leak.
d. Make water unload completely.
e. Reposition the rubber cap (32a) and screw the drain cap (32) (Fig.20).
f. Insert the plug in the power socket.
If the error repeats, please contact an Assistance Centre.
5 - TECHNICAL DATA
For the technical data, please consult the data plate applied to the product (Fig.2).
6 - INCONVENIENCES AND POSSIBLE REMEDIES
MALFUNCTION
The appliance doesn't work.
The appliance doesn't switch on.
CAUSE
No power.
The plug has not been inserted.
LED S9 on
---------------------------------------------------------
In COOLING mode: environment tempera-
ture is lower than the set temperature
WHAT DO I DO?
Wait.
Insert the plug in the power socket.
The water collection tray is full. Switch off the
appliance, unload water from the collection
tray and then restart the appliance.
---------------------------------------------------------
Reset temperature.
DOLCECLIMA BREZZA
>>>>>