Possible Cause(S) - Master MH-16-TTC Manuel De L'utilisateur Et Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Your serial number can be found in the bottom left hand corner of the heater's instruction hang-tag. It
will begin with the letters "PGTT" followed by 8 digits. For Example: PGTT12345678. Have your Se-
rial Number ready before calling customer service at 800-641-6996.
Problem
Unit will not light.
Burner will not stay lit
when gas valve plunger
is released
out of burner, not glowing
/ burn inside the mixing
tube.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A FUEL SOURCE

Possible Cause(s)

1. Valve on propane cylinder
closed.
2. Propane cylinder empty.
3. Regulator not in
4. Defective regulator
1. Tip switch activated or
defective.
2. Wire terminal connections
unplugged.
3. Defective thermocouple.
4. Defective MPU.
1. Air inlet holes blocked or
covered.
2. Burner screen damaged.
3. Gap between burner screen
and burner can.
1. Open cylinder valve by turning
COUNTERCLOCKWISE.
2.
(HI) position.
3. Turn regulator to
4. Replace regulator assembly.
1. Place heater in upright position
or replace tip switch.
2. Check wiring connections.
3. Replace thermocouple.
4. Replace MPU.
1. Clear any obstructions
2. Replace Burner screen.
3. Replace or repair burner head
assembly.
Propane Tank Top Heater User's Manual
11
Solution
(HI) position.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-32-ttcMh-47-ttc

Table des Matières