3.4
Wheeling the machine to the place
of operation (Fig. 3)
When the machine is wheeled to its place of
operation (without scrubbing and suction) it
should be tilted back onto its rear wheels so that
the brush (21) and the squeegee blades (23) are
lifted off the ground. Then wheel the machine to
its place of service.
Push the parking rail (18) downwards by the foot
pedal, and pull back the machine into its parking
position. No weight presses down on the brush
and squeegee blades in this position.
Establishing the mains connection
Turn the movable cable holder (11) upwards,
unwind the power supply cable, and insert the
mains plug (31) into the mains socket. Ensure
that the voltage specified on the machine's rat-
ing plate matches the mains voltage.
3.5
Working with the machine (Fig. 4)
Please ashure that freshwatertank is filled. Tilt
the machine to the back until the parking rail
(18) folds back into the chassis.
The individual units are switched on with the
toggle switch for the water supply (3), the suction
unit (4) and the brush unit (5). All functions are
now ready for operation. All selected functions
are turned on by the red main switch (2) in the
handle.
Press the red main switch (2) and start cleaning.
Scrubbing and suction function during the to and
fro motion of the machine.
Dirty-water switch-off/sensors
Suction is automatically switched off when the
dirty-water tank is full. The suction unit has to be
switched on again with the toggle switch (4) after
the tank has been emptied.