Power / Delay Off
1 POWER / DELAY OFF BUTTON
Power Button Function
-
Button will turn power on and off for entire hood (fan and lights).
- Hood will remember the last speed and light level it was turned off at.
(Example: Press
Button to turn off hood when on fan speed 3 and lights on. Press
again and the hood will turn back on at speed 3 and lights on.)
Delay Off Button Function
- With the fan on press and hold the
5 minute delay off timer will start.
+
remaining until the fan and lights automatically turn off.
- Pressing
Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off
Function.
ACT Verification
- Airflow Control Technology (ACT) allows the installer to set the maximum fan CFM to align with local
codes and regulations.
- To verify the maximum fan CFM:
- With hood off, hold the
default maximum CFM. If 3 fan speed indicators illuminate = 290 maximum CFM.
2 SPEED SELECTION BUTTON
Fan Speed Decrease Button
- Press this button to decrease fan speed. 3, 2, 1.
- If fan is On Speed 1 and this button is pressed, fan will power Off.
Fan Speed Increase Button
- Press this button to increase fan speed. Fan On, 1, 2, 3.
- If hood is Off and this button is pressed, fan will turn On Speed 1.
3 LIGHTS BUTTON
- From off, press one time to power lights on. Press again to power lights off.
4 DISPLAY INDICATORS
Mesh Filter Clean Reminder (always enabled)
- After 30 hours of fan usage, the
clean the mesh filters.
- To reset: With hood off: hold the
confirming the 30 hour timer has been reset.
Adjust 3 Speed Levels
Display (speed level, delay off, filter clean/change)
Button for two seconds. The fan will change to speed 1 and the
LEDs will illuminate and slowly blink in accordance with the time
Button for two seconds. If all five fan speed indicators illuminate =
button indicator will begin to slowly blink indicating it is time to
button for three seconds. All LED indicators will blink two times
12
www.zephyronline.com
Lights On/Off
Button