Cord Sets and Receptacles

Use only high quality, well-insulated, grounded
extension cords with the generator's receptacles.
Inspect extension cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator's manuals of devices for the
manufacturer's recommendations.
A double pole rocker switch main circuit breaker is
provided to protect the locking receptacle. If this circuit
breaker is tripped, all receptacles are disconnected.
WARNING Damaged or overloaded electrical
cords could overheat, arc, and burn
resulting in death or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle.
Connect a 4-wire cord set rated for 250 Volt AC loads
at 30 Amps (or greater). You can use the same 4-wire
cord if you plan to run a 120 Volt load.
4-Wire Cord Set
Y (Hot)
NEMA L14-30
This receptacle powers 120/240 Volt AC, 60 Hz,
single phase loads requiring up to 6,500 watts of
power (6.5 kW) at 27.0 Amps for 240 Volts or two
independent 120 Volt loads at 27.0 Amps each. The
outlet is protected by a two pole rocker switch circuit
breaker.
NOTICE Receptacles may be marked with rating
value greater than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload
Generator.
240V
120V
120V
W (Neutral)
X (Hot)
Ground (Green)
120 Volt AC, 20 Amp, Duplex Receptacle
The duplex receptacle is protected against overload by
a push-to-reset circuit breaker.
Use receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts
(2.4 kW) at 20 Amps of current. Use cord sets that are
rated for 125 Volt AC loads at 20 Amps (or greater).
120 Volt AC, 20 Amp, GFCI Duplex Receptacles
Each GFCI duplex receptacle is protected against
overload by a push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single-
phase, 60 Hz electrical loads requiring up to 2,400 watts
(2.4 kW) at 20 Amps of current. Use cord sets that are
rated for 125 Volt AC loads at 20 Amps (or greater).