TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
OPERATING CURRENT
START-UP CURRENT
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m s.l.m.
(2) Pressure at test point 7)(A)p.12, with zero pressure in the combustion chambre, an maximum burner output.
(2) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output, and measured from a dis-
tance of one meter.
VARIANTS:
Blast tube lenght mm
ACCESSORIES
(optional):
• KIT FOR LPG OPERATION: The kit allows the RS 64/M MZ burner to operate on LPG.
Output kW
Blast tube lenght mm
Code
• KIT FOR MODULATING OPERATION
OUTPUT POWER REGULATOR KIT RWF40
Two components should be ordered:
• the Output power regulator to install on the burner;
• the Probe to install on the heat generator
Parameter to control
Adjustment field
Temperature
- 100...+500°C
0...2.5 bar
Pressure
0...16 bar
• KIT LONG HEAD: code 3010427
• SIGNAL CONVERTER KIT: code 3010390
• POTENTIOMETER KIT FOR THE INDICATION OF LOAD POSITION: code 3010109
• GAS TRAINS TO COUPLE WITH THE BURNER, ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter):
see page 22.
IMPORTANT:
The installer is responsible for the addition of any safety device not forseen in the present manual.
kW
MAX.
Mcal/h
kW
MIN.
Mcal/h
kWh/Sm
Mcal/Sm
kg/Sm
3
Sm
mbar
°C
°C max
V
Hz
rpm
W
V
A
A
V1 - V2
I1 - I2
W max
dBA
–
250 - 385
Probe
Type
PT 100
Output probe
4...20 mA
GAS NATURAL: G20 - G21 - G22 - G23 - G25
3
3
3
/h
• Intermittent (min. 1 stop in 24 hours)
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water, steam, diathermic oil
0 - 40
60
230 - 400 with neutral ~ +/-10%
50 - three-phase
89/336 - 2004/108 - 73/23 - 2006/95 - 2006/42
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
400 - 920
250
Kit long head: 385
3010434
3010435
Output power
regulator
Code
Type
3010110
3010213
RWF40
3010214
10
RS 64/M MZ
08624X - 24386X
400 - 850
345 - 730
150
130
G20
G25
9.45
8.13
8.2
7.0
0.71
0.78
90
104.5
10.7
16.1
2800
1100
220/240 - 380/415
4.8 - 2.8
22 - 13
230 V - 1x15 kV
1 A - 25 mA
1500
IP 40
76
–
CATEGORY
II
2H3B/P
II
II
NL
2L3B/P
II
FR
II
DE
2ELL3B/P
I
BE
2E(R)B,
II
LU
2E3B/P
Code
3010212
GB
2H3P
2Er3P
I
3P