Shutting Down The Unit; Maintenance - Allmand MAXI-POWER MP15XR Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13
A
120V GFCI
Outlets provide 120V power protected by ground
Outlets
fault circuit interrupter (GFCI)
B
GFCI Reset
Resets GFCI Outlets
Buttons
C
Auxiliary
Various auxiliary outlets
Outlets
D
Auxiliary Outlet
Turns the auxiliary outlets on and off
Breakers
See Figure 14 and the table following for the types of
available outlets.
14
A
20 Amp, 120 Volt 2-Pole, 3-Wire Duplex GFCI NEMA 5-20R
B
50 Amp, 120/240 Volt 3-Pole, 4-Wire CS6369 RECEPTACLE
C
30 Amp, 120/240 Volt 3-Pole, 4-Wire Twist Lock NEMA L14-30R
D
30 Amp, 120 Volt, 2-Pole, 3-Wire NEMA TT-30R
14
E
50 Amp, 120/240 Volt 3-Pole, 4-Wire NEMA L14-50R
Power is supplied to the outlets when the engine is running
and the main breaker is ON.
Each outlet is protected by a dedicated circuit breaker. If a
breaker trips:
1. Disconnect the load from the outlet.
2. Shut off the engine.
3. Wait 10 minutes for the generator to cool down.
4. Correct the load problem.
5. Start the engine.
6. Reset the breaker.
Note: Be sure to also check the GFCI breaker on the GFCI
outlet and reset if necessary.
7. Reconnect the load.
8. If the problem persists, see Troubleshooting.

Shutting Down The Unit

1. Shut down the engine. See Operation - Operating The
Engine.
2. The unit is now ready for transport. See Transporting.

Maintenance

Before performing any maintenance, read Safety. 
Scheduled maintenance is necessary for safe and effective
operation of the unit. Under extreme conditions (dusty
conditions, extreme heat or cold, etc.), more frequent
maintenance may be required. 
WARNING
Unsafe Operation Hazard 
• Operating or transporting a machine with worn,
damaged or missing parts could result in death or
serious injury. Replace worn, damaged or missing
parts promptly. Do not operate or transport the machine
until all worn, damaged or missing parts have been
replaced, and proper operation of the machine has
been verified. 
General
 Use the pre-operation checklist as a general maintenance
guideline. See Pre-Operation Checklist. 
Engine
General Engine Maintenance
Refer to the engine operator's manual for all scheduled
engine maintenance procedures (including oil, coolant, filters,
etc.).
Engine Oil Drain
The unit is equipped with a remote engine oil drain (A, Figure
15).

Publicité

Table des Matières
loading

Table des Matières