Read and Save These Safety Precautions
1.
Turn off electricity at main switch before wiring or servicing fan in order to avoid
possible electrical shock.
2.
All wiring must be in accordance with the National Electric Code (ANSI/NFPA
70-1999) and local electrical codes. Electrical installation should be performed by a
qualified licensed electrician.
3.
After making the wire connections, the wires should be spread apart with the grounded
conductor and the equipment-grounding conductor on the one side of the outlet box
and the ungrounded conductor on the other side of the outlet box.
4.
The splices after being made should be turned upward and pushed carefully up into the
outlet box.
5.
Conductor of a fan identified as grounded conductor to be connected to grounded
conductor of power supply, conductor of a fan identified as ungrounded conductor to
be connected to an ungrounded conductor of power supply, conductor of fan
identified for equipment grounding to be connected to an equipment-grounding
conductor.
6.
Fan should not be mounted in an area where it might get wet.
7.
To reduce the risk of fire, electric shock or personal injury, mount to outlet box
marked "Acceptable for Fan Support" and use mounting screws provide with the outlet
box.
8.
For safety and best operating results, we recommend that you have a qualified
electrician assemble and install your fan.
9.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any
solid state speed control device.
10. To reduce the risk of personal injury, do not bend the blade brackets when installing
the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects in
between rotating fan blades.
Before Assembly
1.
Make sure that the fan voltage (120) is compatible with your own electrical system.
2.
Check to make sure that your carton contains all the parts mentioned in the parts list.
NOTE: When the motor is taken out of carton, please put it in a soft cloth to prevent any
damage on the ornamental surface.
CAUTION: Before installing, choose a location for mounting the fan where the blades
have at least 7 feet of clearance from all objects and floor. Mount an outlet box to the
ceiling or use an existing box.
CAUTION: Do not mount fan to sheet rock or drywall type materials. To insure proper
support, use the two #1 wood screws to secure mounting bracket to joist or beam. If the
location you choose does not have a suitable support beam, install a 2"X4" brace between
ceiling joists to support.
Tools You Need
1. Phillips Screwdriver
2. Adjustable Wrench
Problème A : Le ventilateur ne démarre pas
Solution : 1. Vérifiez les fusibles ou le disjoncteur et remplacez-les si besoin est.
Problème B : Le ventilateur fait trop de bruit
Solution : 1. Vérifiez que toutes les vis du ventilateur sont serrées et correctement
Problème C : Le ventilateur oscille
Solution : 1. Vérifiez que toutes les pales sont correctement vissées sur les
3. Needle Nose Pliers
Problèmes fréquents
2. Coupez l'alimentation électrique et vérifiez tous les connecteurs.
3. Vérifiez les interrupteurs on/off ainsi que l'interrupteur de commande
mural. Consultez le mode d'emploi.
installées
2. Assurez-vous que le support de montage est correctement installé.
3. Assurez-vous que le kit d'éclairage et le verre ont été correctement
réinstallés et fixés.
4. Si vous utilisez une commande murale, assurez-vous qu'il ne s'agit pas
d'un transformateur ou d'une commande à vitesse variable.
supports de pales.
2. Vérifiez que tous les supports de pales sont vissés fermement sur le
moteur.
3. Vérifiez le poids des pales. Toutes nos pales sont pesées sur des balances
électroniques. Le poids est marqué sur le dos de la pale, à côté de l'extrémité
du moteur. Toutes les pales doivent avoir le même poids pour que le
ventilateur n'oscille pas.
4. Un kit d'équilibrage des pales est fourni avec l'appareil.
Modèle
Poids (Livres)
AT52
17
CXL42
17
FI52
20.1
P252
21.3
PX52
19
SN52
17
Kilogrammes
7.7
7.7
9.1
9.7
8.6
7.7