START-UP
- Open all the valves and connect the motor.
- Activate the self-priming and wait a reasonable time for this to be completed.
5. MAINTENANCE
- Clean the pre-filter basket regularly to avoid drops in pressure. To prevent the basket from breaking, do not hit it during
the cleaning process.
- Empty the pump if it is to remain at a standstill for a certain length of time, especially in cold countries where there is
a risk of freezing.
- Every time the pre-filter is opened, clean the seal and its seating of any impurities to ensure airtightness when the cap is closed.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person
in order to avoid a hazard.
- Pump components that, due to their normal use, suffer wear and/or tear must be regularly replaced to ensure good pump per-
formance. The following table shows the perishables and/or consumables used in the pump and their estimated working life.
COMPONENT DESCRIPTION
The estimated working life of the parts above has been established according to normal product use and installation conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.
6. TROUBLESHOOTING
1. The pump is not primed
2. The pump releases only a small flow of water
3. The pump makes a noise
1 2 3 4 5 6
6
O rings and general seals
Mechanical seal
Bearings
CAUSES
Air entering the suction pipe
Filter cap badly sealed
Wrong voltage
Pre-filter blocked
Load loss in installation
Pump incorrectly secured
Motor blocked
Increased temperature
The thermal protection trips
For any enquiries on warranties or after-sales service, please contact the vendor
ESTIMATED WORKING LIFE
4. The pump will not start
5. The motor is making a noise but will not start
6. The motor is stopped
Ensure that the clamps and hoses are in the correct position
and have been tightened
Clean the filter cap and check the condition of the rubber seal
Check the voltage on the characteristics plate and
that of the mains
Clean the filter
Prevent parts from causing load loss wherever possible
Secure the pump correctly
Contact the technical service
Contact the technical service
Contact the technical service
NOTE
P-XPERT -
Installation and General Maintenance Manual
1 year
1 year
1 year
SOLUTIONS