9. Specifications
Model: SU30K3/3
Input
Input Voltage
Input Frequency
Voltage Correction Range
Input Current (Per Phase, On-Line)
Inrush Current
Power Factor (Full Load)
Efficiency (Full Load/On-Line)
Circuit Breaker
Input Bypass Circuit Breaker
Output
VA
Watts (Power Factor: 0.8)
Waveform (On-Line)
Waveform (On-Battery)
Output Voltage (RMS)
Output Frequency
Voltage Regulation
Max. Harmonic Distortion
(Non-Linear Full Load)
Overload Capabilities
Short Circuit Capability
Crest Factor
Battery
Battery Type
Battery Pack Quantity
Protection
Typical Backup Time (Half Load)
Typical Backup Time (Full Load)
Operation
On-Line Transfer Time
(Line to Battery, Battery to Line)
Audible Noise (Full Load @ 1 meter)
Indicators
Includes an LCD Display and LEDs (AC Line In, Bypass Line In, AC to DC, DC to AC,
AC Output, Battery Back-Up, Bypass).
Communications
Includes an RS-232 DB9 female connector, an AS-400 DB9 female connector, a dry contact
DB9 female connector and an accessory slot.
Connections
Input Terminal Block
Output Terminal Block
Physical Specifications
Unit Dimensions (H x W x D)
Unit Weight
Shipping Dimensions (H x W x D)
Shipping Weight
+ Backup times are expandable with additional Battery Packs, sold separately. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
( continued )
120/208V AC, 3ø, 4 Wire (plus ground), wye
60 Hz ± 3 Hz
96-144/166-250V AC
90A
<300A
>0.95
>89%
100A (3p)
100A (3p)
30000
24000
Sinewave
Sinewave
120/208V AC, 3ø, 4 Wire (plus ground), wye
60 Hz (± 0.1 Hz on battery)
±2%
<5%
102% (continuous), 102%~125% (1 min.),
125%~150% (30 sec.),
150% (2 sec.)
250A
3:1
Sealed, Lead Acid, 240V DC, 9AH
Three Packs (20 12V DC Batteries per pack)
Six UL-recognized 30A 600VDC rated cartridge
fuses (two per battery pack) and fuse block
(1 per battery pack)
13 min. +
5 min. +
0 ms
<65 dBA
100A
100A
35.3 x 19.3 x 36 in.
662 lb.
43 x 28 x 44.5 in.
750 lb.
1111 W. 35th Street, Chicago, IL 60609 USA
Model: SU30K3/3XR5
Input
Input Voltage
Input Frequency
Voltage Correction Range
Input Current (Per Phase, On-Line)
Inrush Current
Power Factor (Full Load)
Efficiency (Full Load/On-Line)
Circuit Breaker
Input Bypass Circuit Breaker
Output
VA
Watts (Power Factor: 0.8)
Waveform (On-Line)
Waveform (On-Battery)
Output Voltage (RMS)
Output Frequency
Voltage Regulation
Max. Harmonic Distortion
(Non-Linear Full Load)
Overload Capabilities
Short Circuit Capability
Crest Factor
Battery
Battery Type
Battery Pack Quantity
Protection
Typical Backup Time (Half Load)
Typical Backup Time (Full Load)
Operation
On-Line Transfer Time
(Line to Battery, Battery to Line)
Audible Noise (Full Load @ 1 meter)
Indicators
Includes an LCD Display and LEDs (AC Line In, Bypass Line In, AC to DC, DC to AC,
AC Output, Battery Back-Up, Bypass).
Communications
Includes an RS-232 DB9 female connector, an AS-400 DB9 female connector, a dry contact
DB9 female connector and an accessory slot.
Connections
Input Terminal Block
Output Terminal Block
Physical Specifications
Unit Dimensions (H x W x D)
Unit Weight
Shipping Dimensions (H x W x D)
Shipping Weight
www.tripplite.com/support
18
120/208V AC, 3ø, 4 Wire (plus ground), wye
60 Hz ± 3 Hz
96-144/166-250V AC
90A
<300A
>0.95
>89%
100A (3p)
100A (3p)
30000
24000
Sinewave
Sinewave
120/208V AC, 3ø, 4 Wire (plus ground), wye
60 Hz (± 0.1 Hz on battery)
±2%
<5%
102% (continuous), 102%~125% (1 min.),
125%~150% (30 sec.),
150% (2 sec.)
250A
3:1
Sealed, Lead Acid, 240V DC, 9AH
Five Packs (20 12V DC Batteries per pack)
Ten UL-recognized 30A 600VDC rated cartridge
fuses (two per battery pack) and fuse block
(1 per battery pack)
25 min. +
11 min. +
0 ms
<65 dBA
100A
100A
48.5 x 19.3 x 36 in.
935 lb.
61.5 x 31 x 44.5
1152 lb.