Oil change
 Ready a catch bin for appr 1 Litre oil.
 Loosen release screw.
Dispose of old oil ecologically or turn in at a gathering
point.
 Tighten release screw.
 Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifications.
Troubleshooting
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Indicator lamp pump
2x blinking
Leak in the high pressure system
 Check high pressure system and connections for
tightness.
3x blinking
Lack of water after 2 minutes - the pump is
switched off to prevent dry runs.
 Check water supply, check connections.
4x blinking
Heater contactor fault
 Set the appliance switch to "0/OFF".
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
"Low water" indicator lamp
Lack of water - heater is switched off
 Check water supply, check connections.
Indicator lamp "Ready for use" turns off
No line voltage, see "Appliance is not running".
Indicator lamp for heater lights up
Heater operation
Engine indicator lamp
2x blinking
Engine overload/overheat
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
3x blinking
Fault in the voltage supply.
 Check main connections and mains fuse.
4x blinking
Excessive power consumption.
 Check main connections and mains fuse.
 Inform Customer Service.
Indicator lamp boiler fault
1x blinking
Temperature limiter has got triggered.
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service.
3x blinking
System care detection defective
 Inform Customer Service.
4x blinking
Temperature sensor defective
 Inform Customer Service.
Indicator lamp service
Service interval
 Perform service work.
Indicator lamp system care is illuminated
Note: Heater can only operate 5 more hours.
System care bottle empty.
 Replace the system care bottle.
Indicator lamp system care is blinking
Note: Heater operation no longer possible.
System care bottle empty.
 Replace the system care bottle.
Appliance is not running
No power
 Check power connection/conduit.
Device is not building up pressure
Air within the system
Vent pump:
 Set dosing value for detergent to "0".
 With open hand spray gun turn device on and off
multiple times with the device switch.
 Open and close the pressure/quantity regulation at
the pump unit with the hand spray gun open.
Note: By dismantling the high pressure hose from the
high pressure connection the venting process is accel-
erated.
 If detergent tank is empty, refill.
 Check connections and conduits.
Pressure is set to MIN
 Set pressure to MAX.
Sieve in the water connection is dirty
 Clean sieve.
 Clean the fine filter; replace it, if necessary.
Amount of water supply is too low.
 Check water supply level (refer to technical data).
Device leaks, water drips from the bottom of
Pump leaky
Note: 3 drops/minute are allowed.
 With stronger leak, have device checked by cus-
tomer service.
Note: Condensate can cause increased drop genera-
tion on the appliance.
– 6