Oil change
Ready a catch bin for appr 1 Litre oil.
Loosen release screw.
Dispose of old oil ecologically or turn in at a gathering
point.
Tighten release screw.
Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifications.
Troubleshooting
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Indicator lamp pump
2x blinking
–
Leak in the high pressure system
Check high pressure system and connections for
tightness.
3x blinking
–
Lack of water after 2 minutes - the pump is
switched off to prevent dry runs.
Check water supply, check connections.
4x blinking
–
Heater contactor fault
Set the appliance switch to "0/OFF".
Turn on the appliance.
–
Error occurs repeatedly.
Inform Customer Service.
"Low water" indicator lamp
–
Lack of water - heater is switched off
Check water supply, check connections.
Indicator lamp "Ready for use" turns off
–
No line voltage, see "Appliance is not running".
Indicator lamp for heater lights up
–
Heater operation
Engine indicator lamp
2x blinking
–
Engine overload/overheat
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
–
Error occurs repeatedly.
Inform Customer Service.
3x blinking
–
Fault in the voltage supply.
Check main connections and mains fuse.
4x blinking
–
Excessive power consumption.
Check main connections and mains fuse.
Inform Customer Service.
Indicator lamp boiler fault
1x blinking
–
Temperature limiter has got triggered.
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
–
Error occurs repeatedly.
Inform Customer Service.
3x blinking
–
System care detection defective
Inform Customer Service.
4x blinking
–
Temperature sensor defective
Inform Customer Service.
Indicator lamp service
–
Service interval
Perform service work.
Indicator lamp system care is illuminated
Note: Heater can only operate 5 more hours.
–
System care bottle empty.
Replace the system care bottle.
Indicator lamp system care is blinking
Note: Heater operation no longer possible.
–
System care bottle empty.
Replace the system care bottle.
Appliance is not running
–
No power
Check power connection/conduit.
Device is not building up pressure
–
Air within the system
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device on and off
multiple times with the device switch.
Open and close the pressure/quantity regulation at
the pump unit with the hand spray gun open.
Note: By dismantling the high pressure hose from the
high pressure connection the venting process is accel-
erated.
If detergent tank is empty, refill.
Check connections and conduits.
–
Pressure is set to MIN
Set pressure to MAX.
–
Sieve in the water connection is dirty
Clean sieve.
Clean the fine filter; replace it, if necessary.
–
Amount of water supply is too low.
Check water supply level (refer to technical data).
Device leaks, water drips from the bottom of
–
Pump leaky
Note: 3 drops/minute are allowed.
With stronger leak, have device checked by cus-
tomer service.
Note: Condensate can cause increased drop genera-
tion on the appliance.
– 6
EN
the device
19