FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
N.O.
Heater
Black
Relay 1
N.O.
COM
Blue
Red
Figure 15. Machine control electronics (appearance may vary, depending on model).
Accessing the User Interface
and Housing Assembly
1. Access the machine control electronics (see
Accessing the Machine Control Electronics, page
22) and disconnect the P5 ribbon cable.
2. The console panel must be removed to access
the user interface and housing assembly. Remove
the knob from the front of the console panel.
3. The console panel has two locking tabs on the
left and right rear, one locking tab on the bottom
(hidden), and three snap releases across the top.
See figure 16. Press the locking tab on the right
rear, and gently rotate the console panel up as
you pull the top free of the three snap releases,
finally pressing the locking tab on the left, and
lift the console panel off.
User Interface and
Housing Assembly
(inside)
Locking Tabs
Figure 16. Remove the console panel
to access the user interface and housing
assembly.
COM
Lt.
Motor
Blue Black
Red
Relay
Black-White
Tan
White
Green-Yellow
Open
Water Valve Relay
(Steam Models Only)
Snap Releases
Red-White
Removing the User Interface
and Housing Assembly
The user interface and housing assembly is held to
the console panel by screws. Remove the screws
and gently lift the user interface and housing
assembly out of the console panel. See figure 17.
Figure 17. Locate screws (appearance
may vary, depending on model).
PAGE 23
Yellow-Red
Open
Open (Elec.)
Orange (Gas)
Red-White
User Interface and
Housing Assembly