INSTALLATION
Safety
INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
General safety instructions
We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7.
Appliance description
7.1
Standard delivery
The following are delivered with the appliance: DHW sensor
7.2
Required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
7.3
Additional accessories
If it is not possible to insert a rod anode from above, install a
segmented anode.
www.stiebel-eltron.com
8.
Preparations
8.1
Installation location
f Always install the appliance in a room free from the risk of
f
frost and near the draw-off point.
f Ensure the floor is level. Use the adjustable feet to compen-
f
sate for any unevenness in the floor.
f Ensure the floor has a sufficient load bearing capacity (see
f
chapter "Specification / Data table").
f Observe the room height and height when tilted (see chapter
f
"Specification / Data table").
Minimum clearances
The minimum side clearances can be swapped between left and
right.
≥800
f Maintain the minimum clearances.
f
≥300
SBB 200 WP classic |
13