Some Preliminary Remarks; Electrical Connection - Atag ES9011QM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

installation

some preliminary remarks

electrical connection

An extractor hood should be installed in accordance with
national and local regulations. The minimum distance
between the underside of the extractor hood and the hob
should be:
- 60 cm in the case of a ceramic and induction hob;
- 65 cm in the case of a gas hob;
- 75 cm in the case of a gas hob with wok burner.
The appliance should be connected by a registered fitter.
Damage arising from incorrect connection or incorrect fitting
is not covered by the guarantee.
attention: For proper functioning it is important that the
extractor hood is supplied with sufficient fresh air. For this, a
good air supply is necessary in the room in which the
extractor hood is used.
The extractor hood's plug should be accessible after fitting
or the extractor hood should be isolated by a separate
switch.
If the connection cable is damaged, it should be replaced by
the service department of the manufacturer or similarly
qualified persons in order to prevent dangerous situations
from arising.
When making the electrical connections, make sure that the
socket is earthed and that the voltage and frequency
correspond to the values given on the data plate.
GB 7