A technical specifications manual has been included with your bathtub. The Technical Specifications Manual will
contain pertinent information regarding your Jacuzzi Luxury Bath product. Locate the Technical Specifications Manual
at this time.
Frame out the space where the bathtub is to be located. The
following should be taken into consideration when preparing
the area:
Dimensions provided on rough-in diagrams are
nominal. Measure your actual unit upon receipt and
build according to the actual dimensions.
The floor structure beneath the bathtub must be able
to support the total weight of the bathtub, water and
bather.
The unit must be supported from the bottom of the
bathtub and not from the bathtub rim. For drop-in
installations, take into account the thickness of the
surround material and finishing material (marble, tile,
etc.).
Ensure the rim will rest on a level surface.
Per code, access must be provided to the motor/pump
for your specific model. Primary and secondary service
access locations are shown in the rough-in diagrams
contained in the Technical Specifications Manual.
Figure 1 shows common access locations.
It is the responsibility of the installer, building
contractor, or owner to provide access for service.
Jacuzzi is not responsible for any costs relating to
obtaining access for repair. The owner shall bear such
costs and, if appropriate, must seek recovery from the
installer.
Provide adequate ventilation for cooling and supply
sufficient air for the motor/pump. Do not insulate
around the equipment.
Your bathtub may have motor/pump parts that extend
beyond the rim of the bathtub. Refer to the rough-in
diagrams included in the warranty pack and
construction framing to correctly accommodate.
Installation and Operation
Common Access Locations
18˝
(457mm)
36˝
(914mm)
A
= Primary access
B
= Acceptable alternative if access
C
= Secondary access for equipment (optional)
Left hand unit access is on the opposite side (mirror).
www.jacuzzi.com
12˝
Alternate
Secondary
(304mm)
Access
Access
18˝
Blower
(457mm)
Figure 1
B
A
24˝
(609mm)
A
is not possible
Figure 2
12˝
(304mm)
Primary
Access
18˝
(457mm)
20˝
(508mm)
C
Blower
Page 7