12 Technical data

12.1 Mechanical

AISI 316L stainless steel construction
Fastening slots: 4 x Ø11mm (0.43in)
Cable gland holes: 4 x 3/4" NPT + 2 x 1/2" NPT (on
request: 4 x M25 + 2 x M20)
External dimensions (WxHxL): 220x216x240mm
(8.7x8.5x9.4in)
Unit weight: 17.4kg (38.4lb)

12.2 Electrical

MAXIMUS MBX exclusively supports VIDEOTEC
products from the MAXIMUS range with 24Vac and
WASEX with 24Vac.
Maximum power output:
• The output power depends on the VIDEOTEC
product connected.
• The maximum output power is based on the
VIDEOTEC products connected to MAXIMUS MBX.
• Operating temperature from -40°C (-40°F) up to
+25°C (77°F): 120W
• Operating temperature from +25°C (77°F) up to
+70°C (158°F): 60W
Input voltages available:
• 230Vac±10%, 50/60Hz
• 24Vac±10%, 50/60Hz
• 120Vac±10%, 50/60Hz
Possible system configurations:
• up to 1 PTZ + 1 wash system
• up to 2 fixed cameras + 2 wash systems

12.3 Network

4 channels unmanaged ethernet switch:
3 RJ45 ports
• Ethernet connection: 10BASE-T/100BASE-T
1 SFP port (SMALL FORM FACTOR PLUGGABLE)
• Ethernet connection:100BASE-FX
• Supply voltage: 3.3V
• Standard: compliant MSA
The SFP module (not supplied by VIDEOTEC) must
meet the following requirements:
• Laser: Class 1, complies with EN60825-1
• UL/IEC 60950-1 or UL/IEC 62368-1
Certification
MNVCMBXSW_2222_EN

12.4 Video

2 bypass for analog video signals with BNC
connectors

12.5 I/O interface

2 bypass for I / O signals with multi-pin connectors

12.6 Environment

For indoors and outdoors installation
Operating temperature: from -40°C (-40°F) up to
+70°C (158°F)
Relative humidity: from 5% up to 95%

12.7 Certifications

Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN50130-4,
EN55032 (Class B), EN61000-6-3, EN61000-3-2,
EN61000-3-3
RoHS (CE): EN50581
Outdoor installation (CE): EN60950-22, IEC60950-22
Vibration test: EN50130-5, EN60068-2-6
UL certification (UL60950-1, CAN/CSA C22.2 No.
60950-1-07, UL62368-1, CAN/CSA C22.2 No. 62368-1-
14): cULus Listed
Electromagnetic compatibility (North America): FCC
part 15 (Class B), ICES-003 (Class B)
IP protection degree (EN/IEC60529): IP66, IP67, IP68,
IP69
Level of protection Type (UL50E): 4X, 6P
12.8 Certifications - Explosion-
proof applications
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31)
IECEX (IEC 60079-0, IEC 60079-1, IEC 60079-31)
UL listed for USA (UL 60079-0, UL 60079-1, UL 60079-
31)
UL listed for Canada (CAN/CSA-C22.2 NO. 60079-0,
CAN/CSA-C22.2 NO. 60079-1, CAN/CSA-C22.2 NO.
60079-31)
12.9 Certifications - Marine
applications
Lloyd's Register Marine Type Approval certification:
Test Specification Number 1 (ENV1, ENV2, ENV3, ENV5)
Electromagnetic compatibility: EN60945
Salty fog resistance: EN60068-2-52