10. PB2500SMART TROUBLESHOOTING GUIDE
WARNING: Read instruction manual for tool itself together to understand the troubleshooting of tool.
Symptom
Cause
Power does not turn
1. Battery is not fully seated
on.
2. Battery is not fully charged
3. Battery is defective
4. Battery pack has reached operating
temperature limit through continuous
use or defect
Screen freezes in
1. Data reading fails
Stanley Engineered
Fastening Logo.
2. Smart screen is defective
3. Trigger module is defective
4. Setting data are broken
Tool does not operate
1. Screen is not home screen (Counter
when trigger switch is
screen)
pressed.
2. Screen freezes
Even if touch screen, screen doesn not
respond or screen becomes all white.
3. Alarm message is shown with beep
sound.
4. Setting data are broken
5. Radio communication error
Tool shows NOK, even
1. Judgement range setting is not correct Set judgement range correctly
if it sets rivet correctly.
2. Judgement range setting is too small
3. Not fasten 5 rivets in average mode
4. Jaw slips.
5. Tool is not at home position
6. There is a problem in tool.
7. Trigger module is defective.
Tool does not show
1. Judgement range setting is not correct Set judgement range correctly
NOK, even if it sets
2. Judgement range setting is too largel
incorrect rivet
3. Not fasten 5 rivets in average mode
4. There is a problem in tool.
5. Trigger module is defective.
6. Smart function is turned off.
Screen does not show
1. Smart function is turned off.
process curve or does
2. Rivet break load is small, it is under
not show correctly.
3,000N
Remedy
Remove battery and re-insert. Reset
tool to home.
Charge battery
Replace battery
Remove battery & allow to cool.
Mount battery and reset tool to
home.
Remove battery and re-insert. Press
trigger to turn on.
Contact a local service center
Replace motor & module assembly
Restore to factory settings
Change screen to home screen.
Touch "Back home" icon to be back
home.
Remove battery and re-insert. Press
trigger to turn on.
If does not revert, contact local
service center.
Reset alarm refering to the related
pages.
Restore to factory settings
Even if restores to factory settings, if
does not revert, contact local servicre
center.
Set appropriate range
Fasten 5 rivets, if it has an error, do it
again
Do maintenane around jaw area
Reset tool to home
Remove cause of issue or contact
local service center
Replace motor & module assembly or
contact local service center
Set appropriate range
Fasten 5 rivets, if it has an error, do it
again
Remove cause of issue or contact
local service center
Replace motor & module assembly or
contact local service center
No NOK judgement if smart function
is turned off.
If needed, turn on smart function
Turn on smart function
Turn off smart function, if low break
load rivets are used
37
E N G L I S H
Page
Refer to tool
manual
Refer to tool
manual
-
-
-
-
-
31
9
-
each
31
-
15, 16
15, 16
15
Refer to tool
manual
Refer to tool
manual
-
-
15, 16
15, 16
15
-
-
14
14
8, 14