6.0 Maintenance

BEFORE ATTEMPING ANY MAINTENANCE OR
REPAIRS THE MACHINE MUST BE DISCONNECTED
FROM THE AIR AND ELECTRIC SUPPLY.
A. Periodically clean the vertical hexagonal rod with
nonfl ammable liquid detergent. Lubricate with oil (Fig. 6-1).
B. Periodically clean the turntable with a nonfl ammable
liquid detergent, dry and lubricate the sliding surface of
the clamps with oil.
C. Clean the teeth of the clamps (A) with a wire brush,
check the plastic rim protectors (B) and replace if worn
(Fig. 6-2).
D. Periodically wash all plastic parts with cold water and
soap or mild chemical detergent.
E. Periodically lubricate rods of air cylinders with oil.
F. Peridically replaced the plastic insert inside mount/
demount tool.
G. Check the bead breaker pad. Replace if worn.
H. Check and discharge the water every day from air
fi lter/ water separator 'F'. Do this by pulling down the
fi tting "S" (Fig. 6-3).
F
S