Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension
cords with the generator's receptacles. Inspect extension
cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator's manuals of devices for the
manufacturer's recommendations.
A double pole rocker switch main circuit breaker is provided
to protect the locking receptacle. If this circuit breaker is
tripped, all receptacles are disconnected.
WARNING Damaged or overloaded electrical cords
could overheat, arc, and burn resulting in death
or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same 4-wire cord if you plan to
run a 120 Volt load.
4-Wire Cord Set
Y (Hot)
NEMA L14-30
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 7200 watts of power (7.2 kW) at
30 Amps for 240 Volts or two independent 120 Volt loads at
30 Amps each. The outlet is protected by a two pole rocker
switch circuit breaker.
NOTICE Receptacles may be marked with rating value
greater than generator output capacity.
• NEVER attempt to power a device requiring more amperage than
generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload Generator.
16
240V
120V
120V
W (Neutral)
X (Hot)
Ground (Green)
120 Volt AC, 20 Amp, Duplex Receptacles
The generator has two 120 Volt, 20 Amp duplex receptacles.
The receptacles are protected against overload by push-to-
reset circuit breakers.
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Use cord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.

Battery Charger

Use battery float charger jack to keep the starting battery
charged and ready for use. Battery charging should be done
in a dry location, such as inside a garage.
1. Plug charger into unit's "Battery Float Charger" jack,
which is located next to the start switch. Plug battery
charger into a 120 Volt AC wall receptacle.
2. Unplug charger from unit and wall outlet when generator
is being started and while it is in operation.
3. Keep this charger plugged in when generator is not in
use to prolong battery life. The charger has a built in
float equalizer and will not overcharge the battery, even
when plugged in for an extended period of time.
NOTICE See Battery Maintenance for additional information.