Cleaning cooler
For hygienic and healthy reasons, the cooler must be
cleaned once a year. Cleaning must be performed before
changing the cartridge, in order to prevent contamination
of the replacement filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434 001) and the
zugehörige Adapter (Prod. no.: 40 694 or 40 699) could be
ordered at www.grohe.com.
Service
Note the Fault/ Cause/ Remedy table for information on
eliminating problems.
If the problem cannot be rectified, interrupt the power supply
to the cooler. Note down the serial number of the cooler on the
rear of the device and consult a specialist installer or contact
the GROHE Service Hotline via email under
TechnicalSupport-HQ@grohe.com.
The GROHE Blue
®
Chilled cooler may only be repaired by
GROHE Service.
Fault
Cause
Water not flowing
• Water supply interrupted
No filtered water, E2
• Exceeding the running time
in the display
No filtered water, E3
• No connection between fitting and
in the display
cooler
• Cable or connector faulty
No filtered water,
• Fitting and cooler not synchronized
Blue
®
handle flashes
red, E4 in the display
No filtered water,
• Fault function of cooler
®
Blue
handle flashes
red, E5 in the display
No filtered water,
• Values range does not concur
Blue
®
handle flashes
red, E6 in the display
No filtered water, E7
• Fault function of cooler
in the display
• Filter capacity exceeded
®
Blue
handle flashes
orange, E8 in the
display
No filtered water,
• Cooler overheated
®
Blue
handle flashes
red, E9 in the display

Environment and recycling

Used filter cartridges can be disposed of hazard-free in
domestic waste.
The cooler is an electrical device, to which return and take-
back obligations apply in many countries. GROHE participates
in such take-back systems in all relevant countries.
This category of device does not belong in
the domestic waste, but must be disposed of
separately in accordance with the relevant
local national regulations.
Remedy
- Open shut-off valves
®
- Close Blue
handle
- Connect plug-in connector
- Contact GROHE Service
- Synchronise with one another, see section
Installation
- Connect mains supply, wait 30 seconds and
reconnect
- Synchronise with one another, see section
Installation
- Connect mains supply, wait 30 seconds and
reconnect
- Change filter cartridge immediately
®
- Close Blue
handle, ensure ventilation and reduce
ambient temperature to max. 32 °C
6