Ec Declaration Of Conformity - Binks AA4400M Instructions De Service

Masquer les pouces Voir aussi pour AA4400M:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
EN
The Spray Gun models listed in the following declaration of conformity may be used in some potentially explosive atmospheres ONLY when the
special conditions for safe installation and operation have been followed as expressed in this user manual (Part Sheet). These models are
approved to ATEX regulations 94/9/EC, protection level: II 2 G X: Suitable for use in Zones 1 and 2.
This Product is designed for use with:
Suitable for use in hazardous area:
Protection Level:
Vibration Level:
Sound Pressure Level:
Sound Power Level:
Manufacturer:

EC Declaration of Conformity

We: Finishing Brands UK, declare that the above product conforms with the Provisions of:
Machinery Directive 2006/42/EC
ATEX Directive 94/9/EC
by complying with the following statutory documents and harmonised standards:
BS EN 1953:2013 Atomising and spraying equipment for coating materials – Safety requirements
EN ISO 12100-1:2010 Safety of Machinery – Basic concepts, general principles for design – Basic terminology, methodology
EN ISO 12100-2:2010 Safety of Machinery – Basic concepts, general principles for design – Technical principles
EN 14462:2015 Surface treatment equipment – Noise test code for surface treatment equipment including its ancillary handling equipment –
Accuracy grades 2 and 3
EN ISO 11201:2010 Acoustics – Noise by machinery and equipment – Determination of emission sound pressure levels at a work station and at
other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections
EN ISO 20643:2008 Mechanical vibration – Hand held and hand guided machinery – Principles for evaluation of vibration emission
EN ISO 28662-1 Hand-held portable power tools – Measurement of vibrations at the handle
EN 12096:1997 Mechanical vibration – Declaration and verification of vibration emission values
EN1127-1:2011 Explosive atmospheres – Explosion prevention – Basic concepts
EN 13463-1:2009 Non electrical equipment for use in potentially explosive atmospheres – Basic methods and requirements
The spray gun must be earthed to dissipate any electrostatic charges which may be created by fluid or air flows.
This can be achieved through the spray gun mounting, or conductive air/fluid hoses. Electrical bond from the spray
gun to earth should be checked and a resistance of less than 10
Solvent and water based materials
Zone 1 & 2
II 2 G X
N/A
Available on request
Available on request
Carlisle Fluid Technologies
320 Philips Ave.
Toledo, OH 43612
WARNING
!
2 / 13
Chuck McCulloch
December 31, 2015
Ohms is required.
6