CU-PD084
FADER
REPEAT
6
1
1
2
INPUT SELECTOR
DIGITAL
COAX
OPT
AES/
EBU
RECORD
4
5
or / ou / o
6
62
<PRE1282>
En
1
4
2
5
6
4
R-800
REC
TRACK NO.
WRITE
5
2
3
OPEN/
CLOSE
ANALOG
XLR
+4dBu
XLR
–8dBu
LINE
REC
RECORDING (4) – MANUAL DIGITAL-
SOURCE RECORDING
This recording mode is for recording digital
signals from sources other than CD, DAT, MD
or DCC.
(Automatic digital-source synchro recording is recommended
when recording from CD, DAT, MD or DCC.)
The following instructions explain how to perform manual
digital-source recording.
• Connect the digital input correctly to the coaxial, optical or
AES/EBU input sockets.
1
Load a CD-R or CD-RW disc containing space
for recording. If the disc is finalized, recording
will not be possible.
÷ After loading the disc check the CD-R or CD-RW indicator
stops blinking and lights steadily.
2
Select the input to be used for recording with
the INPUT SELECTOR.
÷ Select optical, coaxial, or AES/EBU input.
3
Ensure the source device is in pause or stop
mode and the correct program is ready to play.
4
Press the RECORD button or the two RECORD
buttons on the remote control unit. When
recording starts, start playing the source
device.
5
With AUTO TRACK ON
÷ Using SPDIF input, the unit will increment the track number
each time an ID or CD track flag is detected in the digital
input signal.
÷ Using AES/EBU input, the unit will increment the track
number each time the signal level falls below the set
threshold (AT - xx dB) for more than 2 seconds.
÷ With AUTO TRACK OFF, no incrementing of track numbers
will occur.
6
After recording is complete, press the 7 button
to end the recording.
÷ The display will show "PMA REC" while recording the track
data and then the unit stops recording.