IMPORTANT SAFEGUARDS – PLEASE MAKE THIS
PRECAUTIONS LIST AVAILABLE TO ALL USERS and
WARNINGS:
1.
THIS DEVICE IS NOT INTENDED FOR LIFE SUPPORT.
2.
If oxygen is used with the device, the oxygen flow must be turned off when the device is not in use.
Explanation of the Warning: When the device is not in operation and the oxygen flow is left on, oxygen delivered
into the tubing may accumulate within the device's enclosure and create a risk of fire.
3.
Oxygen supports combustion. Oxygen should not be used while smoking or in the presence of an open flame.
4.
Always ensured the device is generating airflow before the oxygen supply is turned. Always turn off the oxygen
supply before stopping the airflow from the device.
5.
This device should not be used in the vicinity of a flammable anesthetic mixture in combination with oxygen or air
and nitrous oxide.
6.
The airflow for breathing generated by this device may be as much as 7°C (12.6° F) higher than the room
temperature. This device should not be used if the room temperature is warmer than 35°C (95°F) to prevent the
airflow temperature from exceeding 40° C (104° F) and causing irritation to your airway.
7.
If this device overheats, it will stop operating and show "Error 002" on the display. After cooling down to proper
temperature, the device can restart again.
8.
This machine should be used only with masks (and connectors) recommended by the manufacturer, or by your
physician or respiratory therapist. A mask should not be used unless the
CPAP machine is turned on and operating properly. The vent holes associated with the mask should never be
blocked for proper exhaling purpose. If the vent hole is blocked, the CPAP machine will stop and show message
"Error 002", after cooling down, please re-connect the
9.
At low CPAP pressure, some exhaled gas may remain in the mask and be re-breathed.
CAUTION –
Make sure the environment around the machine is dry and clean. Dust and foreign particles may
1.
affect the treatment. Keep the air inlet on the back of the machine clear to prevent overheating and damage of the
device. Do not place the machine near a source of hot or cold air. Extreme cold or hot environment may damage
user's respiratory airway.
2.
If there is a possibility of electro-magnetic interference with mobile phones, please increase the distance between
devices or turn off the mobile phone.
3.
Do not connect the device to the personal computer for data downloading during the treatment. This may cause
the CPAP system failure.
4.
To prevent from potential allergic reactions to mask used in the device, This machine shall be used only with
masks (and connectors) recommended by the manufacturer.
5.
U.S. Federal law restricts this device to sale by or on the order of a licensed physician.