Table des Matières

Publicité

Manual BVS 12 ATEX E 056
6.3

Technical Details

General
Mounting
inside hazardous area
PS 850 S . . . / PS 850 S . . . BY1 .
II 2G Ex e mb [ib] [px] IIC T6 Gb
II 2G Ex e mb [ib] [px] IIC T4 Gb
II 2D Ex tb [ib] [p] IIIC T70°C Db IP 65
Type of protection
PS 850 S . . . HT / PS 850 S . . . HT.BY1, .
II 2G Ex e mb [ib] [px] IIC T4 Gb
PS 860 S . . . / PS 860 X . . . BY1, .
II 2G Ex e mb [ib] [px] IIC T6 Gb
II 2G Ex e mb [ib] [px] IIC T4 Gb
Environment protection
IP65 (without considering the blow-off opening)
Housing
Dimensions
H x B x T: 220 mm x 120 mm x 90 mm
Material
Aluminum, lacquered / Ral 7035
Power consumption
ca. 2,5 VA (without peripherals)
Electrical
24 V DC, 24 V AC, 110 V AC, 120 V AC, 220 V AC, 230 V AC
specifications
Main voltage
48 ...62 Hz
Working circuits terminal 11,
AC: U ≤ 250VAC, I ≤ 5A at cos > 0,7
12, 13, 14
DC: U ≤ 30 VDC, I ≤ 5 A, P ≤ 150 W
Control circuits
Protection by increased safety Ex ib IIC
Terminal 5, 6, 10
8,61 V
Terminal 7,8
8,61 V
Terminal 4
8,61 V
Terminal 1, 9
8,61 V
Terminal 2
Terminal 3
8,61 V
Min. and max.
min. 0,3 Nm
Ex e Anschluss -
clamping torque
max. 0,4 Nm
klemme
Min. and max. wire cross-
steep: 0,2 – 2,5 mm²
section
flexible: 0,2 – 2,5 mm²
Pneumatic
Pressure range
0 – 22 mbar
Flow rate range
dependent upon plate orifice size
Position independent, only inlet and outlet of the control unit should be
Mounting
Position
lined up on a horizontal axis.
–10°C ... 45°C at T6
Ambient temperature
–10°C ... 60°C at T4
Humidity
5 – 95 %, non-condensing
Pressurized air Class 533 according to ISO 8573-1
= particle 40 m (Class 5) / dew-point -20°C (Class 3)/ oil 1 mg/m³ (Class 3)
Quality
If necessary, depending on the requirements of the built-in equipment in
the Ex-p enclosure, the air quality shall be better.
Ex p
LC-Display, menu guided
Parameter input
Configuration
Different languages: German, English, French, Dutch, Spanish
Storage
by EEPROM double saved with CRC
Edition January 2016
Copyright
C-17
–20°C ≤ TA ≤ 45°C
–20°C ≤ TA ≤ 60°C
–20°C ≤ TA ≤ 60°C
–20°C ≤ TA ≤ 70°C
–20°C ≤ TA ≤ 45°C
–20°C ≤ TA ≤ 60°C
6 mA
13 mW
20µH
digital input
160 mA
20µH
digital input
10 mA
22 mW
2 µF, 10 mH digital output
51 mA
110 mW
2 µF, 10 mH digital output
frame terminal
20 mA
44 mW
2 µF, 10 mH digital output
thuba Ltd., CH-4015 Basel
Switzerland
Edition January 2016
Copyright
D1
Lufteintritt
Entrée air
Air inlet
thuba Ltd., CH-4015 Basel
Switzerland

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ps 860 s

Table des Matières