Dräger PIR 7000 Notice D'utilisation page 23

Masquer les pouces Voir aussi pour PIR 7000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
calibration gas, default setting
zero-point
span
calibration gas, possible settings
calibration gas
calibration gas concentration
calibration range limits for:
zero-point default setting
possible settings
span default setting
possible settings
maintenance signal, default setting
possible settings
fault signal, default setting
possible settings
beam block warning, default setting
possible settings
warning signal, default setting
5)
possible settings
response characteristics, default setting
possible settings
SIL lock, default setting
possible settings
5) When the warning signal is active, the fault signal is transmitted every 10 seconds for 0.7 seconds in case of warning.
Dräger PIR 7000 Type 334
0 % LEL
methane, 50 % LEL
selectable within the measured gases
selectable within the measuring range
50 % (corresponds to 1.5 % LEL)
0...100 % (corresponds to 0...3 % LEL)
33 % (corresponds with 5 % of the configured calibration gas concentration)
0...100 % (corresponds with 0...15 % of the configured calibration gas concentration)
constant, 0.7...3.6 mA or alternating, 3 mA for 0.4 s / 5 mA for 0.7 s
Dräger PIR 7000 Type 340
0 % LEL
propane, 50 % LEL
constant, 3 mA
<1.2 mA
0.7...3.6 mA
inactive, 2 mA
active / inactive, 0.7 to 3.6 mA
inactive
active / inactive
normal
normal / fast
OFF
ON / OFF
Dräger PIR 7200
0 % vol.
carbon dioxide, 4 % vol.
carbon dioxide
selectable within the measuring
range
45 % (0.013 % vol.)
0...100 % (0...0.03 % vol.)
33 % (5 % of calibration gas con-
centration)
0...100 % (0...15 % of the config-
ured calibration gas concentra-
tion)
www.norrscope.com
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pir 7200

Table des Matières