Section 4. Operation; Start-Up - Jandy Stealth SHPF.50 Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 12
ENGLISH
WARNING
When pressure testing the system with water, it is
very important to make sure that the pump basket
lid on the filter pump is completely secure.
WARNING
Do not pressure test above 35 PSI. Pressure test-
ing must be done by a trained pool professional.
Circulation equipment that is not tested properly
can fail, which could result in severe injury or prop-
erty damage.
1.
Fill the system with water, using care to
eliminate trapped air.
2.
Pressurize the system with water to no more
than 35 PSI.
3.
Close the valve to trap pressurized water in the
system.
4.
Observe the system for leaks and/or pressure
decay.
5.
If there are lid leaks, repeat steps 1-3. For
technical support, call 800.822.7933.
6.
Discard the blue pressure test o-ring after
successfully completing the test.

Section 4. Operation

4.1

Start-up

CAUTION
Never run the pump without water. Running the
pump "dry" for any length of time can cause severe
damage to both the pump and motor and may void
the warranty.
If this is a new pool installation, make sure all piping
is clear of construction debris and has been properly
pressure tested. The filter should be checked for
proper installation, verifying all connections and
clamps are secure according to the manufacturer's
recommendations.
|
Jandy
Stealth
Pumps
Operation Manual
®
To avoid risk of property damage, severe personal
injury, or death, verify that all power is turned off
before starting this procedure.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
WARNING
Release all pressure from the system and open
the filter pressure release valve.
If the pump is located below the water level
of the pool, opening the filter pressure release
valve will prime the pump with water.
If the pump is located above the water level of
the pool, remove the lid and fill the basket with
water before starting the pump.
Prior to replacing the lid, check for debris
around the lid o-ring seat. Debris around the lid
o-ring seat will cause air to leak into the system,
and make it difficult to prime the pump.
Hand-tighten the lid to make an air tight seal.
Do not use any tools to tighten the lid, hand-
tighten only. Make sure all valves are open and
the unions are tight.
Turn on the power to the pump. Then turn on
the pump.
For 3-Phase motors - confirm direction of motor
rotation matches the directional arrow on the
pump. Failure to do so may cause pump failure,
and may also void warranty.
Once all the air has left the filter, close the
pressure release valve.
The pump should prime. The time it takes to
prime will depend on the elevation and length
of pipe used on the suction supply pipe. See
Section 3.1.3.3 for proper elevation and pipe
size.
If the pump does not prime and all the
instructions to this point have been followed,
check for a suction leak and then repeat Steps 2
through 7.

Publicité

Table des Matières
loading

Table des Matières