EN
Electrical equipment
Switching input
Switching output
Operating voltage U
Current consumption
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accor-
dance with the NEC (National Electric Code).
Indicators and operational controls
Individual LEDs
LED strip
Membrane keyboard
Mechanical data
Housing
Connection technology
Degree of protection
Dimensions (HxWxD in mm)
2
26
+18 ... +30 V DC
Transmitter not active – no data transmission
0 ... 2 V DC
Transmitter active – normal function
+18 ... +30 V DC: received signal level/
SIGNAL QUALITY ok
Normal operating range
0 ... 2 V DC: intensity warning
SIGNAL QUALITY
+18 ... +30 V DC
B
Approx. 200 mA at 24 V DC (no load at switch-
ing output)
Operating status LEDs, operating mode LEDs in
the control panel Status display of the Ethernet
connection
Received signal level LEDs in the control panel
(SIGNAL QUALITY)
Operating mode selector switch [MODE] in the
control panel
Diecast aluminum
Optical window: glass
M12 connectors
IP65 in accordance with EN 60529 with
screwed-on M12 connectors or mounted caps
Devices with operating range 40 m / 120 m
156 x 100 x 99.5
Devices with operating range 200 m
156 x 100 x 122.5