Kollmann
Machine Care
Motor driven equipment must be kept indoors or well
covered in rainy weather. If machine has been exposed to
freezing weather, unit must be run for ten or twenty min-
utes without load to warm up. Failing to do this will result
in frozen bearings. If machine is exposed to weather for a
period of time, moisture will form across motor windings
causing motor to burn out. Such an occurance, due to ne-
glect, will jeopardize your warranty of equipment.
Cables
Cables should be thoroughly flushed with water to pre-
vent damaging effects of drain cleaning compounds.
Periodically, lubricate cables and couplings with oil.
When not in use, store cables indoors to prevent deteri-
oration by the elements.
Cables should be replaced when they become severely
corroded or worn. A worn cable can be identified when
outside coils of cable become flat.
K-75A/B & K-1500A/B Wiring Diagram
115V
Motor
K-75A/B, K-1500A/B, & K-1500SP Drain Cleaning Machines
Green
Blue
Red
Black
Yellow
Switch
Ridge Tool Company • Elyria, Ohio • U.S.A.
Service & Repair
If any maintenance is required other than that outlined, the
tool should be sent to a RIDGID Independent Authorized
Service Center or returned to the factory. All repairs made
by Ridge service facilities are warranted against defects in
material and workmanship.
If you have any questions regarding the operation or
function of this tool, call or write to:
Ridge Tool Company
Technical Service Department
400 Clark Street
Elyria, Ohio 44036-2023
Phone: 800-519-3456
If any correspondence, please give all information shown
on the nameplate of your tool including model number,
voltage, and serial number.
Green
White
Black
Service Cord
9