Typical installation
A
B
C
D
E
F
G
H
I
Avoid unnecessary curves and narrow on both the discharge and suction pipes. Apply a 3/8 " or ½" BSP female nipple
on the conduct of the plant to be treated, in the most suitable location for the injection of the product to be dosed. This nipple
is not supplied. Screw the injection valve on the nipple using PTFE tape as a seal (Figure 8). Connect the tube to the conical
adapter of the injection valve and secure with the hose ring nut (4). The injection valve is also a no-return valve.
1.
2.
3.
4.
5.
6.
Accessories
Supplied with the pump are includes the following articles:
28 ENGLISH
Main pipeline
Injection valve
Backpressure valve
Pressure gauge
Relief valve
Power supply plug
Chemical tank
Foot filter
Level probe
Plant being treated
conical connection 3/8" – ½" BSP
injection valve
hose ring nut
discharge pump hose
PTFE sealing type
n.1 flexible transparent PVC cristal suction hose, length 4m
•
n.1 polyethylene semi-rigid white discharge hose, length 2m
•
n. 1 3/8" BSP injection valve
•
n.1 foot filter
•
n.1 instruction manual
•
Fig. 6 – Typical installation
Fig. 7 - Injection valve mounting