Dismantlement
To dismantle the pump or before performing pump maintenance, proceed as follows:
Make sure the pump is electrically deactivated (both poles) by disconnecting the conductors from the power
supply using the omnipolar switch which must have a minimum distance of 3mm between its contacts (Fig.3).
Relieve the pressure in the pump head and the discharge tube in the most adequate way possible (be very
careful during this operation).
Drain the liquid present in the pump head by disassembling and reassembling the pump head using the four
fixing screws, tightening torque 180÷200 N*cm (Appendix 1).
Please pay particolar attention to this last point and we recommend the user to consult the enclosed drawings and
chapter "RISKS" before starting any operations.
Warranty
2 years (normal wear on parts is excluded, i.e.: valves, fittings, piping ring nuts, piping, filter and injection valve).
Improper equipment use invalidates the warranty. The warranty is intended ex works or at an authorized distributor.