After-cooler Discharge Pressure (TAS units only) – Pressure the
compressor is delivering before the dryer.
Pages 2 Thru 4 – Compressor Data
Figure 116 : Compressor Data
Compressor Data:
•
Power ON Hours – Number of hours that the controller has been
powered up
•
Running Hours – Number of hours the compressor's motor has been
running
•
Motor Speed – Current speed of the motor in RPM
•
Time – Current time of day.
•
Motor Current – Electrical current currently being drawn by the motor.
•
Motor Voltage – Electrical voltage at the motor.
•
DC Link Voltage – DC Bus Voltage on the VSD
•
Package kW – Instantaneous power consumption of the compressor
•
Heatsink Temperature – Temperature of the VSD at the heatsink
•
Control Card Temperature – Temperature of the VSD at the control card
Pages 5 & 6 – Digital Inputs
EN-52
Figure 117 : Digital Inputs
Digital Inputs: (Password Required)
Each digital input will have an indication showing whether the input is in
an "OPEN" or "CLOSED" state. This is the physical state of the input and may
not necessarily line up with the logical condition. The normal state is shown
below.
•
Emergency Stop – Normally Closed
•
Main/Fan Motor Overload – Normally Closed
•
Remote Start - Normally Open
•
Remote Stop – Normally Closed
•
Dryer Temperature Fault – Normally Open
•
Dryer High Pressure – Normally Closed
Pages 7 & 8 – Digital Outputs
Figure 118 : Digital Outputs
Digital Outputs (Password Required):
Each digital output will have an indication showing whether the output is in
an "OPEN" or "CLOSED" state. This is the physical state of the input and may
not necessarily line up with the logical condition. The normal state is shown
below.
•
VSD Run K1 Contact – Normally Open
•
Fan Starter Contact KM4 – Normally Open
•
Blowdown Solenoid 1SV – Normally Open
•
Dryer Run / Fan Run – Normally Open
•
PORO Horn – Normally Open
•
Trip Indication – Normally Open