7.4
ASSEMBLY OF THE SQUEEGEE
Lower the squeegee by pressing theFoot levers
(photo B-19).
Lightly tighten the two thumbscrews (photo H-28) on
the squeegee (photo H-44).
Insert the squeegee into its seat on the squeegee
holder (photo G-45) and fasten by tightening the two
toggle screws.
Slide the suction hose of the suction device (photo
G-27) onto the connecting piece of the squeegee.
7.5
DISASSEMBLY OF THE SUCTION BARS
Lower the squeegee by pressing the foot lever
(Photo B-19).
Disconnect the suction hose from the squeegee
(Photo G-27).
Screw away the two thumbscrews (photo G-45).
Lift the squeegee holder (photo H-44) and remove
the squeegee.
7.6
CHANGING THE SQUEEGEE LIPS
Release the squeegee from its holder
(see 7.5). Fully unscrew the knob screws (I-31) and
remove the locksmith screws (I-24) until the (I-30)
can be removed.
Remove the squeegee lips from the holder.
Insert the new squeegee into the plastic holder
by pushing the plastic pins into the corresponding
holes on the squeegee. Replace the mounting strip
in the squeegee and fasten it by screwing on the
thumbscrews (I-30).
Replace the squeegee onto its holder (I-31).
7.7
INSERTING AND REMOVING THE
SPLASH GUARD
- Loosen the 2 screws of the splash guard (A-12).
- Open the latch on the splash guard (A-12).
- Remove the splash guard.
7.8
FILLING AND EMPTYING THE FRESH
WATER TANK
• The temperature of the water or cleaning
agent to be filled must not exceed 50 °C.
☞ Whenever the fresh water tank is filled, the
waste water tank must always be emptied.
Fill:
- Remove the filler neck (A-9).
- Do not fill the tank to the brim.
- Add the required amount of cleaning agent, ob-
ser-ving the concentration specified by the manufac-
turer. The fresh water tank of your Torana holds 30
litres.
- When using cleaning agents, make sure that these
are suitable for the respective floor.
• Only use the Torana with modern,
non-foaming cleaners. The use of other
chemical products, such as caustic soda, ox-
idants, solvents or hydrocarbons can lead to
damage or destruction of the machine.
- If in doubt, contact the cleaning agent manufacturer
or Sprintus to ensure the suitability of the cleaning
agent.
- Always put the cleaning agent into the tank already
filled with water to prevent foam from forming.
• Do not leave the water hose unattended with water
when filling the tank and guide it fully into the tank.
Otherwise there is a risk of water penetrating to the
electrical parts and damaging them.
7.8.1 FILL LEVEL INDICATOR OF THE
FRESHWATER TANK
The fill level of the freshwater tank can be deter-
mined with the transparent hose attached to the
rear of the machine (Fig. B-46).
7.8.2 EMPTYING THE FRESHWATER TANK
Emptying the tank with the cleaning liquid can be
performed with the transparent hose located at the
rear of the machine (Fig. B-46).
- Remove the hose from its holder and position it
over a tank or drain. - Remove the plug used to
seal the hose (Fig. B-46) and wait until the tank is
completely empty.
- After emptying, seal the hose with the plug and
insert it back into its holder.
7.9
DRAINING THE WASTE WATER TANK
When disposing of the waste water, the regulations
of the respective country of application must be fol-
lowed. The user is liable for observing these laws.
If the cleaning solution is used up, the waste water
tank must be emptied completely before refilling the
fresh water tank.
In general, the waste water tank can be emptied as
often as desired and also during the intermediate
phases of the work cycle.
• The capacity of the collecting tank is greater than
the capacity of the cleaning solution tank, which is
why a potential risk to the suction motor should be
excluded. Nevertheless, for safety, there is a float
(F-43), which interrupts the suction flow as soon as
the waste water level is too high.
• If water or foam leakage is detected under the
tanks, stop the suction motor immediately and drain
the waste water tank.
Emptying the tank:
Move the machine to a place suitable for draining the
waste water, i.e. as close as possible to a toilet or
waste water drain (follow the wastewater disposal
laws in the country of use of the machine).
Make sure that the main switch on the control panel
is switched off (E-32).
Remove the drain hose (A-7 / A-8) from its holder,
hold the hose upwards and open the sealing plug.