Description of the icons.
Black: S.S.S. system on.
Orange: Distilled water tank NOT pressurized.
Black: Distilled water tank in reserve and active.
Red: Distilled water tank in reserve but NOT active.
M.W.B. system on.
Black: Disinfectant liquid tank in reserve and active.
Red: Disinfectant liquid tank in reserve but NOT active.
Blue: COLD water-to-glass.
Orange: WARM water-to-glass.
Red: HOT water-to-glass.
Pantograph arm brake/CART board locked.
Peristaltic pump on.
Green: wireless foot control battery charged.
Orange: wireless foot control battery 50% charged.
Red: wireless foot control battery fl at.
Green: wireless foot control connected and active.
Orange: wireless foot control connected but not active.
Red: searching for connection to the wireless foot control.
5.1.1. User interface
When turned on, the dental unit performs a brief autodiagnosis cycle that
ends when the main screen containing the name of the operator last set is
displayed.
As of this moment a number of settings can be edited from user-friendly
menus (see diagram).
How to navigate the various menus.
• Press button MENU to go from one icon to another.
• After selecting an icon, press multifunction button OK to enter the relative
submenu.
• Press multifunction button ESC to go back to the previous screen.
• Press buttons INCREASE and/or DECREASE to edit the values.
Layout of the user interface menu.
The user interface menu is structured as shown in the diagram and includes
the following menus:
5.1.1.1.
Operator settings.
5.1.1.2.
GENERAL SETTINGS.
5.1.1.2.1. Adjusting display contrast.
5.1.1.2.2. Language selection.
5.1.1.2.3. Adjusting/engaging the pantograph arm's brake.
5.1.1.2.4. Entering the operator's personal identifi cation.
5.1.1.2.5. Chronometer.
5.1.1.2.6. Setting the time.
5.1.1.2.7. Selecting your favourite button.
5.1.1.2.8. LAEC setting (only with LAEC).
5.1.1.3.
SETTING THE DISINFECTING SYSTEMS.
5.1.1.3.1. Setting the disinfecting cycle (only with AUTOSTERIL system).
5.1.1.3.2. Setting the Time Flushing cycle (only with Time Flushing).
5.1.1.3.3. Emptying the M.W.B. tank (only with M.W.B. system).
5.1.1.4.
SETTING THE HYDROGROUP.
5.1.1.4.1. Setting water deliver to bowl.
5.1.1.4.2. Setting water deliver to cup.
5.1.1.4.3. Movement control (only with powered bowl).
Error message.
During the autodiagnosis cycle the dental unit may detect malfunctions
inside the system.
If an error message appears, it remains on the display until the operator
presses the OK button. (see paragraph 10.).
If the malfunction is not dangerous, the dental unit remains operative.
96
96
96
GB
EN
SKEMA 6
- OPERATING INSTRUCTION
Dental chair storage activated.
Dental chair position automated programme 1.
Dental chair position automated programme 2.
Dental chair position automated programme 3.
Dental chair position automated programme 4.
Dental chair position: automatic rinsing position program.
Dental chair position: automatic dental chair reset position program.
Dental chair motion blocked.
15:24