Electrical Safety; Description Of Device / Spare Parts - ATIKA KGSZ 305 N Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
 removal of faults (this also includes the removal of
jammed splinters)
 checks of connecting lines, whether these are knotted or
damaged
 Transporting the machine
 Changing the saw blade
 Leaving the machine (also for short-term interruption)
 When saw is not in use
 Maintain your machine with care:
 Keep your tools sharp and clean in order to be able to
work better and safer.
 Follow the maintenance instructions and the instructions
for tool exchange.
 Keep handles dry and free of oil and grease.
 Check the machine for possible damage:
 Before further use of the machine the protection devices
or slightly damaged parts must be checked carefully for
their proper and intended function.
 Check whether the movable parts function perfectly and
do not stick or whether the parts are damaged, All parts
must be correctly installed and fulfil all conditions to
ensure perfect operation of the saw
 Damaged guards and parts must be properly repaired or
exchanged by a recognized, specialist workshop; insofar
as nothing else is stated in the instructions for use.
 Damaged or illegible security labels have to be replaced.
 Do not allow any tool key to be plugged in!
Before switching on, check always that wrenches and
adjusting tools are removed.
 Store the unused machine in a dry locked place away from
the reach of children.
 Make sure that only spacer disks and spindle rings are used
which are suited for the purpose indicated by the
manufacturer.

Electrical safety

 Design of the connection cable according to IEC 60 245 (H
07 RN-F) with a core cross-profile section of at least
 1.5 mm
for cable lengths up to 25 m
2
 2.5 mm
for cable lengths over 25 m
2
 Long and thin connection lines result in a potential drop. The
motor does not reach any longer its maximal power; the
function of the device is reduced.
 Plugs and coupler outlets on connection cables must be
made of rubber, non-rigid PVC or other thermoplastic
material of same mechanical stability or be covered with this
material.
 The connector of the connection cable must be splash-proof.
 When running the connection line observe that it does not
interfere, is not squeezed, bended and the plug connection
does not get wet.
 Do not use the cable for purposes for which it is not meant.
Protect the cable against heat, oil and sharp edges. Do not
use the cable to pull the plug from the socket.
 Wind off completely the cable when using a cable drum.
 Regularly check the extension cables and replace them if
they are damaged.
 Do not use any defective connection cables.
 When working outdoors, only use extension cables
especially approved and appropriately labelled for outdoor
use.
 Do not set up any provisional electrical connections.
 Never bypass protective devices or deactivate them.
 Only hook up the machine by means of a fault-current circuit
breaker (30 mA).
The electrical connection or repairs to electrical parts of the
machine must be carried out by a certified electrician or
one of our customer service points. Local regulations –
especially regarding protective measures – must be
observed.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such
action.

Description of device / Spare parts

 Please refer to the attached assembly and
operating instruction sheet.
Pos. Order-no. Designation
1
Handle with On/Off switch
1A
On/Off switch
1B
Laser switch
2
Carrying handle
3
Motor
4
366012
Carbon brush cover
5
Transport locking pin
6
Set screw for the pulling device
7
366054
Locking lever for the rotary table adjustment
7A
Rotary table locking
8
Rotary table
9
366055
Table insert
10
Indicator for mitre angle
11
366056
Work piece stop
11A
366057
RH additional stop
11B
Locking screw for RH additional stop
11C
366058
LH attachment
11D
Locking screw for LH attachment
12
Set screw for work piece stop
13
Laser head
14
Locking screw for the laser
15
Protective cover
16
Pendulum cover
16A
Holder for the pendulum cover
17
Lock for pendulum cover
18
366059
Support arm
19
Wing screw for support arm
20
Vice assembly
366060
21
Star grip nut for vice assembly
19

Publicité

Table des Matières
loading

Table des Matières