Technical data

Property
Backset
Centres distance
Handle follower
Rebate gap in variants for
single-leaf doors
Rebate gap in variants for
double-leaf doors
Bolt throw
Face plate
· Width
· Height
· Thickness
Material
· Lock case
· Bolt
· Latch
· Face plate
Rigidity/protection:
· Deadbolt counterforce Deadbolt
· transverse shear stress
Installation position
Operating temperature
Corrosion resistance
Maximum motorised unlocking time
Unlocking under pre-load with
rated operating voltage
Rated operating
voltage,,
Rated current consumption
· Idle state, lock is locked
· Motor operation
Connecting cable length, with use of
mains adapter 1003-24-4

Updated information

Updated information, such as reports on current fire testing, can be found online
at: www.assabloy.de
35 mm, 40 mm, 45 mm,
55 mm, 65 mm, 80 mm
92 mm
9 mm
2 mm – 6 mm
4 mm – 8 mm
20 mm
509N
24 mm
446 mm
6 mm
Stainless steel / Zinc diecast
Steel 60 HRC (hardened surface)
Steel
Steel, chrome-plated
6,000 N
20,000 N
Vertical
–10°C – +60°C
high corrosion resistance (96 h)
1 seconds
50 N (motorised unlocking)
regulated
24 V DC ± 15 %
50 mA
Max. 2.2 A for 1.5 s
10 m with Ø 0.25 mm²
519N
24 mm
1760 mm
6 mm
Technical data

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Onesystem 519n