20
A
Interior Light - Turns on lights inside engine compartment
B
Tower Lift Switch - see Operation - Raising And Lowering The
Light Tower
C
Deep Sea Mode Switch
D
Deep Sea Unit
To shut down the engine
Key-start models
1. Turn the key switch to OFF.
LSC / Deep Sea models
1. See the LSC / Deep Sea Manual for LSC / Deep Sea
shutdown procedures.
2. Set the LSC / Deep Sea mode switch to OFF.
Automatic engine shutdown
The engine is equipped with an automatic engine shutdown
system to prevent excessive engine damage in the event of
low oil pressure or high coolant temperature. For additional
information, refer to the engine operator's manual.
Operating The Tower Lights
Raise the light tower before operating the tower lights.
See Operation - Raising And Lowering The Light Tower.
To turn lights on
1. Open the left engine compartment access door (A,
Figure 21). Locate the main breaker (B) on the rear wall.
Turn the main breaker to ON.
21
20
2. Turn the individual light breakers (A, Figure 22) (1 - 4 or 1
- 6, depending on model) to ON.
To turn lights off
1. Turn the individual light breakers (1 - 4 or 1 - 6,
depending on model) to OFF.
2. Turn the main breaker to OFF.
22
Auxiliary AC Outlets
Units come equipped with a variation of auxiliary AC outlets.
See Figure 23 and the table following.
23
A
120V GFCI
Outlets provide 120V power protected by ground
Outlets
fault circuit interrupter (GFCI)
B
GFCI Reset
Resets GFCI Outlets
Buttons
C
Auxiliary
Various auxiliary outlets
Outlets