LiftMaster CB22 Instructions page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
CONTROL BOX CONFIGURATION
POINT
DESCRIPTION
1
M1, terminals:1,2,3
2
M2, terminals:4,5,6
3
M3, terminals:7,10
Terminals:8,10
Terminals:9,10
Terminals:11,12
Terminals:12,13
Terminals:14,15
4
M4, terminals:16,19
Terminals:17,19
Terminals:18,19
Terminals:20,21
Terminals:22,23
5
CN4/CN5, connector
6
CH1, pushbutton
7
CH2, pushbutton
8
L1, pushbutton
9
JMP1, jumper
10
DIP1
11
PT4, potentiometer
12
PT3, potentiometer
13
PT2, potentiometer
14
PT1, potentiometer
15
CN2, connector
16
CN3, connector
17
CN1, connector
FUNCTION
Feeder cable
Drive
Impulse transmitter channel 1
Impulse transmitter channel 2
Emergency-stop push-button / must
be bridged without switch connected
Gate monitor/lighting
Flashing lamp
Connection for accessories 24V
Optional photocell OPEN
Optional photocell CLOSED
Main photocell CLOSED
Contact strip 8.2 kilo ohms
Antenna
Radio module sockets
Learn/Delete radio channel 1
Learn/Delete radio channel 2
Learning the distance covered
Programming the photocell
Dip switch block
RPM sensor setting
Force setting
Automatic closing
Brake
Magnetic limit switch
RPM sensor
E-lock
DESCRIPTION OF THE LEDs
RED LEDs should be switched off. Indication of faults to be rectified;
this does not apply to failsafe photocells not connected. (see
"photocell" description)
(Example: short circuit, photocells and/or contact strip)
POINT
DESCRIPTION
LED A
RED Learn/Delete radio channel 1
LED B
RED Start impulse channel 1
LED C
RED Learn/Delete radio channel 2
LED D
RED Start impulse channel 2
LED E
RED photocell active for OPEN
LED F
RED photocell active for CLOSE
LED G
RED photocell active for CLOSE
LED H
RED contact strip
LED I
GREEN stop
LED J
YELLOW limit switch gate OPEN
LED K
YELLOW limit switch gate CLOSED
LED L
RED learn program (distance covered)

Publicité

Table des Matières
loading

Table des Matières